{"title":"现场EMC测试及抗干扰","authors":"T. Schrader, K. Munter, C. Jastrow, Ahmad Daneschnejad, T. Kleine-Ostmann","doi":"10.1109/ISEMC.2009.5284583","DOIUrl":null,"url":null,"abstract":"Complex measurement systems being assembled on site have been found to suffer from electromagnetic interference although components of the systems passed the required electromagnetic compatibility (EMC) tests. We present an on-site test system that allows for the EMC evaluation of on-site assembled large measuring system installations in the frequency range from 27 MHz up to 5.8 GHz and propose a solution for interference prevention therein. E.g. weigh bridges for large vehicles and other measuring instruments being subject to legal metrology must not display readings influenced by radio frequency fields [1–3]. A multi-sensor system integrated into the electronics detects any unintentional RF signals coupled into the measuring device and prevents further processing of measured data which are likely being disturbed by RF energy coupled into the system.","PeriodicalId":268582,"journal":{"name":"2009 IEEE International Symposium on Electromagnetic Compatibility","volume":"206 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"On-site EMC testing and interference prevention\",\"authors\":\"T. Schrader, K. Munter, C. Jastrow, Ahmad Daneschnejad, T. Kleine-Ostmann\",\"doi\":\"10.1109/ISEMC.2009.5284583\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Complex measurement systems being assembled on site have been found to suffer from electromagnetic interference although components of the systems passed the required electromagnetic compatibility (EMC) tests. We present an on-site test system that allows for the EMC evaluation of on-site assembled large measuring system installations in the frequency range from 27 MHz up to 5.8 GHz and propose a solution for interference prevention therein. E.g. weigh bridges for large vehicles and other measuring instruments being subject to legal metrology must not display readings influenced by radio frequency fields [1–3]. A multi-sensor system integrated into the electronics detects any unintentional RF signals coupled into the measuring device and prevents further processing of measured data which are likely being disturbed by RF energy coupled into the system.\",\"PeriodicalId\":268582,\"journal\":{\"name\":\"2009 IEEE International Symposium on Electromagnetic Compatibility\",\"volume\":\"206 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-10-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE International Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2009.5284583\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2009.5284583","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

在现场组装的复杂测量系统中,尽管系统的组件通过了要求的电磁兼容性(EMC)测试,但仍然存在电磁干扰。本文提出了一种现场测试系统,可以对现场组装的大型测量系统在27mhz ~ 5.8 GHz的频率范围内进行EMC评估,并提出了一种抗干扰解决方案。例如,大型车辆的称重桥和其他受法定计量的测量仪器不得显示受射频场影响的读数[1-3]。集成到电子器件中的多传感器系统检测耦合到测量装置中的任何无意的射频信号,并防止对可能被耦合到系统中的射频能量干扰的测量数据进行进一步处理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On-site EMC testing and interference prevention
Complex measurement systems being assembled on site have been found to suffer from electromagnetic interference although components of the systems passed the required electromagnetic compatibility (EMC) tests. We present an on-site test system that allows for the EMC evaluation of on-site assembled large measuring system installations in the frequency range from 27 MHz up to 5.8 GHz and propose a solution for interference prevention therein. E.g. weigh bridges for large vehicles and other measuring instruments being subject to legal metrology must not display readings influenced by radio frequency fields [1–3]. A multi-sensor system integrated into the electronics detects any unintentional RF signals coupled into the measuring device and prevents further processing of measured data which are likely being disturbed by RF energy coupled into the system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信