{"title":"光伏发电系统中混合电池直流侧容量的确定","authors":"Shinya Hashimoto, Toshikazu Yamamoto, K. Nara, Nozomi Tobaru","doi":"10.1109/ISGT-Asia.2019.8881162","DOIUrl":null,"url":null,"abstract":"Lots of studies are published to mitigate the photovoltaic (PV) power output fluctuation by using batteries. Especially, under the islanding operation of the microgrid, the PV output fluctuation causes the instability of the system. Although batteries are installed to mitigate the instability, a control delay of the batteries affects the frequency and voltage of the micro-grid extensively. Generally, a control delay inevitably exists since the PV output is measured at every designated discrete time period and the control signal is sent to the batteries after calculating the difference between load and PV power output. Therefore, so as to reduce this time delay influences, the authors have proposed so called \"PV system with hybrid batteries\" which has two types of the batteries (AC side battery and DC side battery). In this system, since the DC side battery absorbs only the power fluctuation caused by the control delay of the AC side battery, the size of the DC side battery seems to be very small. The purpose of this paper is to develop a method to estimate the size of the DC side battery. Through the qualitative discussions, the maximum necessary capacity can be estimated from the amount of charge or discharge of the DC side battery when the PV output fluctuation cycle is the same as the one of the PV output measurement. The size of the DC side battery calculated by the developed method is verified through the real system applications.","PeriodicalId":257974,"journal":{"name":"2019 IEEE Innovative Smart Grid Technologies - Asia (ISGT Asia)","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Capacity Determination of the DC-side Battery for Hybrid Batteries in PV Generation System\",\"authors\":\"Shinya Hashimoto, Toshikazu Yamamoto, K. Nara, Nozomi Tobaru\",\"doi\":\"10.1109/ISGT-Asia.2019.8881162\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Lots of studies are published to mitigate the photovoltaic (PV) power output fluctuation by using batteries. Especially, under the islanding operation of the microgrid, the PV output fluctuation causes the instability of the system. Although batteries are installed to mitigate the instability, a control delay of the batteries affects the frequency and voltage of the micro-grid extensively. Generally, a control delay inevitably exists since the PV output is measured at every designated discrete time period and the control signal is sent to the batteries after calculating the difference between load and PV power output. Therefore, so as to reduce this time delay influences, the authors have proposed so called \\\"PV system with hybrid batteries\\\" which has two types of the batteries (AC side battery and DC side battery). In this system, since the DC side battery absorbs only the power fluctuation caused by the control delay of the AC side battery, the size of the DC side battery seems to be very small. The purpose of this paper is to develop a method to estimate the size of the DC side battery. Through the qualitative discussions, the maximum necessary capacity can be estimated from the amount of charge or discharge of the DC side battery when the PV output fluctuation cycle is the same as the one of the PV output measurement. The size of the DC side battery calculated by the developed method is verified through the real system applications.\",\"PeriodicalId\":257974,\"journal\":{\"name\":\"2019 IEEE Innovative Smart Grid Technologies - Asia (ISGT Asia)\",\"volume\":\"76 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Innovative Smart Grid Technologies - Asia (ISGT Asia)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGT-Asia.2019.8881162\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Innovative Smart Grid Technologies - Asia (ISGT Asia)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-Asia.2019.8881162","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

利用电池来缓解光伏输出功率波动的研究已经发表了很多。特别是在微电网孤岛运行的情况下,光伏输出的波动会导致系统的不稳定。虽然安装了电池来减轻不稳定性,但电池的控制延迟对微电网的频率和电压有很大的影响。由于光伏输出是在每一个指定的离散时间段进行测量,并且在计算出负载与光伏输出的差值后将控制信号发送给蓄电池,因此一般不可避免地存在控制延迟。因此,为了减少这种时滞影响,作者提出了所谓的“混合电池光伏系统”,该系统有两种类型的电池(交流侧电池和直流侧电池)。在这个系统中,由于直流侧电池只吸收交流侧电池控制延迟引起的功率波动,所以直流侧电池的尺寸看起来非常小。本文的目的是开发一种估算直流侧电池尺寸的方法。通过定性讨论,当光伏输出波动周期与光伏输出测量周期相同时,可通过直流侧电池的充放电量估算出最大所需容量。通过实际系统应用,验证了该方法计算的直流侧电池尺寸。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Capacity Determination of the DC-side Battery for Hybrid Batteries in PV Generation System
Lots of studies are published to mitigate the photovoltaic (PV) power output fluctuation by using batteries. Especially, under the islanding operation of the microgrid, the PV output fluctuation causes the instability of the system. Although batteries are installed to mitigate the instability, a control delay of the batteries affects the frequency and voltage of the micro-grid extensively. Generally, a control delay inevitably exists since the PV output is measured at every designated discrete time period and the control signal is sent to the batteries after calculating the difference between load and PV power output. Therefore, so as to reduce this time delay influences, the authors have proposed so called "PV system with hybrid batteries" which has two types of the batteries (AC side battery and DC side battery). In this system, since the DC side battery absorbs only the power fluctuation caused by the control delay of the AC side battery, the size of the DC side battery seems to be very small. The purpose of this paper is to develop a method to estimate the size of the DC side battery. Through the qualitative discussions, the maximum necessary capacity can be estimated from the amount of charge or discharge of the DC side battery when the PV output fluctuation cycle is the same as the one of the PV output measurement. The size of the DC side battery calculated by the developed method is verified through the real system applications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信