孤岛运行中的汽轮机控制

Štefan Korčak, Tomáš Hába, K. Máslo
{"title":"孤岛运行中的汽轮机控制","authors":"Štefan Korčak, Tomáš Hába, K. Máslo","doi":"10.1109/EPE51172.2020.9269246","DOIUrl":null,"url":null,"abstract":"This paper deals with steam and gas turbine-governor dynamic models. The paper compares various control modes and different settings of parameters applied in special cases of separated and island operations. Simulation calculations on dynamic models show that in these modes it is necessary to have a functional speed governor and vice versa deactivate the load/power controller. This solution prevents frequency collapse and ensures a secure separated and island operation.","PeriodicalId":177031,"journal":{"name":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","volume":"68 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Turbine Control in Island Operation\",\"authors\":\"Štefan Korčak, Tomáš Hába, K. Máslo\",\"doi\":\"10.1109/EPE51172.2020.9269246\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with steam and gas turbine-governor dynamic models. The paper compares various control modes and different settings of parameters applied in special cases of separated and island operations. Simulation calculations on dynamic models show that in these modes it is necessary to have a functional speed governor and vice versa deactivate the load/power controller. This solution prevents frequency collapse and ensures a secure separated and island operation.\",\"PeriodicalId\":177031,\"journal\":{\"name\":\"2020 21st International Scientific Conference on Electric Power Engineering (EPE)\",\"volume\":\"68 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 21st International Scientific Conference on Electric Power Engineering (EPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPE51172.2020.9269246\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 21st International Scientific Conference on Electric Power Engineering (EPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPE51172.2020.9269246","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本文研究了蒸汽和燃气轮机调速器的动态模型。本文比较了分离孤岛作业特殊情况下的各种控制方式和不同参数设置。动态模型的仿真计算表明,在这些模式下,有必要有一个功能的调速器,反之亦然,停用负载/功率控制器。该解决方案可防止频率崩溃,并确保安全的隔离和孤岛操作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Turbine Control in Island Operation
This paper deals with steam and gas turbine-governor dynamic models. The paper compares various control modes and different settings of parameters applied in special cases of separated and island operations. Simulation calculations on dynamic models show that in these modes it is necessary to have a functional speed governor and vice versa deactivate the load/power controller. This solution prevents frequency collapse and ensures a secure separated and island operation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信