一种具有扩展软开关范围的紧凑双向功率转换系统方案

Liang Jia, S. Mazumder
{"title":"一种具有扩展软开关范围的紧凑双向功率转换系统方案","authors":"Liang Jia, S. Mazumder","doi":"10.1109/ESTS.2009.4906529","DOIUrl":null,"url":null,"abstract":"This paper outlines a soft-switching modulation scheme based on zero-current-switching (ZCS) principle with extended range for the front-end isolated dc/dc converter of an isolated three-phase rectifier-type high-frequency-link (RHFL) power converter. General modulation methodology and optimization conditions are presented, and with the help of linear programming, the optimum solution for a particular objective function can be achieved to implement the proposed ZCS scheme. In conjunction with a back-end ac/ac converter operating with a novel patent-filed hybrid modulation scheme which reduces the number of hard-switched commutation per switching cycle, the proposed ZCS scheme can also realize zero-voltage-switching (ZVS) on secondary side rectifier to improve the overall efficiency further. With the nonzero pulsating dc output, the proposed ZCS scheme is effective even without an active clamp circuit, and it is suitable for applications where low-voltage dc to high-voltage three-phase ac power conversion is required.","PeriodicalId":446953,"journal":{"name":"2009 IEEE Electric Ship Technologies Symposium","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A compact bi-directional power-conversion system scheme with extended soft-switching range\",\"authors\":\"Liang Jia, S. Mazumder\",\"doi\":\"10.1109/ESTS.2009.4906529\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper outlines a soft-switching modulation scheme based on zero-current-switching (ZCS) principle with extended range for the front-end isolated dc/dc converter of an isolated three-phase rectifier-type high-frequency-link (RHFL) power converter. General modulation methodology and optimization conditions are presented, and with the help of linear programming, the optimum solution for a particular objective function can be achieved to implement the proposed ZCS scheme. In conjunction with a back-end ac/ac converter operating with a novel patent-filed hybrid modulation scheme which reduces the number of hard-switched commutation per switching cycle, the proposed ZCS scheme can also realize zero-voltage-switching (ZVS) on secondary side rectifier to improve the overall efficiency further. With the nonzero pulsating dc output, the proposed ZCS scheme is effective even without an active clamp circuit, and it is suitable for applications where low-voltage dc to high-voltage three-phase ac power conversion is required.\",\"PeriodicalId\":446953,\"journal\":{\"name\":\"2009 IEEE Electric Ship Technologies Symposium\",\"volume\":\"51 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-04-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE Electric Ship Technologies Symposium\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESTS.2009.4906529\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE Electric Ship Technologies Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESTS.2009.4906529","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了一种基于零电流开关(ZCS)原理的宽量程软开关调制方案,用于隔离型三相整流型高频链路(RHFL)功率变换器的前端隔离dc/dc变换器。给出了一般调制方法和优化条件,并利用线性规划的方法求出特定目标函数的最优解,从而实现所提出的ZCS方案。结合采用新型专利混合调制方案的后端ac/ac变换器,减少了每个开关周期的硬开关换流次数,所提出的ZCS方案还可以在二次侧整流器上实现零电压开关,进一步提高整体效率。采用非零脉动直流电输出,即使没有有源箝位电路,该方案也能有效地工作,适用于低压直流电到高压三相交流电源转换的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A compact bi-directional power-conversion system scheme with extended soft-switching range
This paper outlines a soft-switching modulation scheme based on zero-current-switching (ZCS) principle with extended range for the front-end isolated dc/dc converter of an isolated three-phase rectifier-type high-frequency-link (RHFL) power converter. General modulation methodology and optimization conditions are presented, and with the help of linear programming, the optimum solution for a particular objective function can be achieved to implement the proposed ZCS scheme. In conjunction with a back-end ac/ac converter operating with a novel patent-filed hybrid modulation scheme which reduces the number of hard-switched commutation per switching cycle, the proposed ZCS scheme can also realize zero-voltage-switching (ZVS) on secondary side rectifier to improve the overall efficiency further. With the nonzero pulsating dc output, the proposed ZCS scheme is effective even without an active clamp circuit, and it is suitable for applications where low-voltage dc to high-voltage three-phase ac power conversion is required.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信