并网孤岛模式下小水电厂电压频率响应

D. Maina, M. Sanjari, N. Nair
{"title":"并网孤岛模式下小水电厂电压频率响应","authors":"D. Maina, M. Sanjari, N. Nair","doi":"10.1109/AUPEC.2018.8757944","DOIUrl":null,"url":null,"abstract":"Hydro-based power is gaining more interests as the penetration level of small-scale hydro power plants are being increased to the medium voltage network. This paper investigates the performance of a single unit small hydropower plant in both grid-connected and islanded operation. The overexcitation and volt/hertz excitation limiters have been included in the study to compare their responses in both modes of operation. The plant is evaluated under different loading scenarios considering both resistive and inductive loads. A PI tertiary control for speed reference setting in islanded operation is introduced in the governor to enable regaining of 50 Hz frequency after load changes. The results obtained from the simulation study show the importance and difference of analysing different loading scenarios both in grid-connected and island modes. Also, the inclusion of PI control in governor aids in returning the frequency to its nominal value.","PeriodicalId":314530,"journal":{"name":"2018 Australasian Universities Power Engineering Conference (AUPEC)","volume":"47 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Voltage and Frequency Response of Small Hydro Power Plant in Grid Connected and Islanded Mode\",\"authors\":\"D. Maina, M. Sanjari, N. Nair\",\"doi\":\"10.1109/AUPEC.2018.8757944\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Hydro-based power is gaining more interests as the penetration level of small-scale hydro power plants are being increased to the medium voltage network. This paper investigates the performance of a single unit small hydropower plant in both grid-connected and islanded operation. The overexcitation and volt/hertz excitation limiters have been included in the study to compare their responses in both modes of operation. The plant is evaluated under different loading scenarios considering both resistive and inductive loads. A PI tertiary control for speed reference setting in islanded operation is introduced in the governor to enable regaining of 50 Hz frequency after load changes. The results obtained from the simulation study show the importance and difference of analysing different loading scenarios both in grid-connected and island modes. Also, the inclusion of PI control in governor aids in returning the frequency to its nominal value.\",\"PeriodicalId\":314530,\"journal\":{\"name\":\"2018 Australasian Universities Power Engineering Conference (AUPEC)\",\"volume\":\"47 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 Australasian Universities Power Engineering Conference (AUPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AUPEC.2018.8757944\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 Australasian Universities Power Engineering Conference (AUPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AUPEC.2018.8757944","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

随着小型水力发电厂向中压电网渗透水平的提高,水力发电越来越受到人们的关注。本文研究了单机小水电厂在并网运行和孤岛运行两种情况下的运行性能。研究中还包括过激励和伏特/赫兹激励限制器,以比较它们在两种工作模式下的响应。在考虑电阻性和感性负载的不同负载情况下,对该装置进行了评估。在调速器中引入了孤岛运行速度基准设定的PI三级控制,使负载变化后的频率恢复到50 Hz。仿真研究结果表明,在并网和孤岛模式下,分析不同荷载情况的重要性和差异。此外,在调速器中包含PI控制有助于将频率返回到其标称值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Voltage and Frequency Response of Small Hydro Power Plant in Grid Connected and Islanded Mode
Hydro-based power is gaining more interests as the penetration level of small-scale hydro power plants are being increased to the medium voltage network. This paper investigates the performance of a single unit small hydropower plant in both grid-connected and islanded operation. The overexcitation and volt/hertz excitation limiters have been included in the study to compare their responses in both modes of operation. The plant is evaluated under different loading scenarios considering both resistive and inductive loads. A PI tertiary control for speed reference setting in islanded operation is introduced in the governor to enable regaining of 50 Hz frequency after load changes. The results obtained from the simulation study show the importance and difference of analysing different loading scenarios both in grid-connected and island modes. Also, the inclusion of PI control in governor aids in returning the frequency to its nominal value.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信