A. Ceccarelli, I. Majzik, D. Iovino, F. Caneschi, G. Pintér, A. Bondavalli
{"title":"列车控制系统的弹性SIL 2驱动机接口","authors":"A. Ceccarelli, I. Majzik, D. Iovino, F. Caneschi, G. Pintér, A. Bondavalli","doi":"10.1109/DepCoS-RELCOMEX.2008.33","DOIUrl":null,"url":null,"abstract":"In railway train-borne equipment, the driver machine interface (DMI) acts like a bridge between the train driver and the onboard automatic train control system (European Vital Computer, EVC). While the DMI is required to operate in a critical context, current DMIs have no safety requirements. This implies that the EVC may automatically stop the train whenever the DMI is suspected to misbehave, leading to delay of the train, inconvenience for passengers and consequent possible profit loss. For these reasons a DMI with higher safety requirements is worth to be taken into account, even if it implies higher costs. The SAFEDMI European project aims at developing (i) a DMI at Safety Integrity Level 2 (SIL 2) using off-the-shelf components and a simple hardware architecture to reduce costs, and (ii) a SIL 2 wireless communication support for maintenance. This paper describes the architecture of a DMI which satisfies these objectives. The main hardware and software characteristics will be shown, including the proposed error detection techniques and the related fault handling (characterized by a new operational mode that allows DMI to restart silently, thus reducing unexpected train stops).","PeriodicalId":167937,"journal":{"name":"2008 Third International Conference on Dependability of Computer Systems DepCoS-RELCOMEX","volume":"153 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"A Resilient SIL 2 Driver Machine Interface for Train Control Systems\",\"authors\":\"A. Ceccarelli, I. Majzik, D. Iovino, F. Caneschi, G. Pintér, A. Bondavalli\",\"doi\":\"10.1109/DepCoS-RELCOMEX.2008.33\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In railway train-borne equipment, the driver machine interface (DMI) acts like a bridge between the train driver and the onboard automatic train control system (European Vital Computer, EVC). While the DMI is required to operate in a critical context, current DMIs have no safety requirements. This implies that the EVC may automatically stop the train whenever the DMI is suspected to misbehave, leading to delay of the train, inconvenience for passengers and consequent possible profit loss. For these reasons a DMI with higher safety requirements is worth to be taken into account, even if it implies higher costs. The SAFEDMI European project aims at developing (i) a DMI at Safety Integrity Level 2 (SIL 2) using off-the-shelf components and a simple hardware architecture to reduce costs, and (ii) a SIL 2 wireless communication support for maintenance. This paper describes the architecture of a DMI which satisfies these objectives. The main hardware and software characteristics will be shown, including the proposed error detection techniques and the related fault handling (characterized by a new operational mode that allows DMI to restart silently, thus reducing unexpected train stops).\",\"PeriodicalId\":167937,\"journal\":{\"name\":\"2008 Third International Conference on Dependability of Computer Systems DepCoS-RELCOMEX\",\"volume\":\"153 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-06-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Third International Conference on Dependability of Computer Systems DepCoS-RELCOMEX\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DepCoS-RELCOMEX.2008.33\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Third International Conference on Dependability of Computer Systems DepCoS-RELCOMEX","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DepCoS-RELCOMEX.2008.33","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
摘要
在铁路车载设备中,驾驶员机接口(DMI)是连接列车驾驶员和车载自动列车控制系统(EVC, European Vital Computer)的桥梁。虽然DMI需要在关键环境中运行,但目前的DMI没有安全要求。这意味着EVC可以在怀疑DMI行为不当时自动停止列车,导致列车延误,给乘客带来不便,从而可能造成利润损失。由于这些原因,具有更高安全要求的DMI值得考虑,即使它意味着更高的成本。SAFEDMI欧洲项目旨在开发(i)使用现成的组件和简单的硬件架构来降低成本的安全完整性等级2 (SIL 2)的DMI,以及(ii)支持维护的SIL 2无线通信。本文描述了满足这些目标的DMI体系结构。将展示主要的硬件和软件特性,包括建议的错误检测技术和相关的故障处理(以允许DMI静默重启的新操作模式为特征,从而减少意外的列车停靠)。
A Resilient SIL 2 Driver Machine Interface for Train Control Systems
In railway train-borne equipment, the driver machine interface (DMI) acts like a bridge between the train driver and the onboard automatic train control system (European Vital Computer, EVC). While the DMI is required to operate in a critical context, current DMIs have no safety requirements. This implies that the EVC may automatically stop the train whenever the DMI is suspected to misbehave, leading to delay of the train, inconvenience for passengers and consequent possible profit loss. For these reasons a DMI with higher safety requirements is worth to be taken into account, even if it implies higher costs. The SAFEDMI European project aims at developing (i) a DMI at Safety Integrity Level 2 (SIL 2) using off-the-shelf components and a simple hardware architecture to reduce costs, and (ii) a SIL 2 wireless communication support for maintenance. This paper describes the architecture of a DMI which satisfies these objectives. The main hardware and software characteristics will be shown, including the proposed error detection techniques and the related fault handling (characterized by a new operational mode that allows DMI to restart silently, thus reducing unexpected train stops).