{"title":"共接地电流比较器的自校准","authors":"Wenfang Liu, Xianlin Pan, Zhenyu Jin, Yonghong Zhu, Ying Song, Jiangtao Zhang","doi":"10.1109/CPEM.2016.7540736","DOIUrl":null,"url":null,"abstract":"A method to measure the phase angle errors and amplitude errors of the current comparators with ratio of 2:1, 5:1 and 10:1 has been described. The method is based on the use of the differential current transformer to determine the current relationship of the current comparator. The measurements have been done at frequencies from 10 kHz to 100 kHz, and the results are presented.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Self-calibration of the current comparator with common ground\",\"authors\":\"Wenfang Liu, Xianlin Pan, Zhenyu Jin, Yonghong Zhu, Ying Song, Jiangtao Zhang\",\"doi\":\"10.1109/CPEM.2016.7540736\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A method to measure the phase angle errors and amplitude errors of the current comparators with ratio of 2:1, 5:1 and 10:1 has been described. The method is based on the use of the differential current transformer to determine the current relationship of the current comparator. The measurements have been done at frequencies from 10 kHz to 100 kHz, and the results are presented.\",\"PeriodicalId\":415488,\"journal\":{\"name\":\"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)\",\"volume\":\"9 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPEM.2016.7540736\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2016.7540736","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Self-calibration of the current comparator with common ground
A method to measure the phase angle errors and amplitude errors of the current comparators with ratio of 2:1, 5:1 and 10:1 has been described. The method is based on the use of the differential current transformer to determine the current relationship of the current comparator. The measurements have been done at frequencies from 10 kHz to 100 kHz, and the results are presented.