脉动电压下油纸绝缘的产气特性

Lianwei Bao, Jian Li, Xiao Lei, P. Sun, Jin Zhang
{"title":"脉动电压下油纸绝缘的产气特性","authors":"Lianwei Bao, Jian Li, Xiao Lei, P. Sun, Jin Zhang","doi":"10.1109/CEIDP.2013.6748161","DOIUrl":null,"url":null,"abstract":"On-line monitoring of dissolved gas in oil is one of effective methods of condition assessment of transformers. Compared with the power transformer, valve side windings of converter transformer withstand pulsating voltage during the converter process. This paper presents gas generation properties of oil insulation under pulsating voltages, which are different from those under individual AC voltage. Three discharge models were designed and lots of partial discharge experiments were carried out to research the variation characteristics of dissolved gases in oil under pulsating voltages. The increment of gases concentration in oil during the progress of s of different discharge models were analyzed, the experiment results under pulsating voltages showed that the dissolved gas component content was obviously different under pulsating voltage and pure AC voltage. The results can provide the basis experimental data for condition assessment of converter transformer by using the method of online monitoring of dissolved gas in oil.","PeriodicalId":393969,"journal":{"name":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Gas generation properties of oil-paper insulation under pulsating voltage\",\"authors\":\"Lianwei Bao, Jian Li, Xiao Lei, P. Sun, Jin Zhang\",\"doi\":\"10.1109/CEIDP.2013.6748161\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"On-line monitoring of dissolved gas in oil is one of effective methods of condition assessment of transformers. Compared with the power transformer, valve side windings of converter transformer withstand pulsating voltage during the converter process. This paper presents gas generation properties of oil insulation under pulsating voltages, which are different from those under individual AC voltage. Three discharge models were designed and lots of partial discharge experiments were carried out to research the variation characteristics of dissolved gases in oil under pulsating voltages. The increment of gases concentration in oil during the progress of s of different discharge models were analyzed, the experiment results under pulsating voltages showed that the dissolved gas component content was obviously different under pulsating voltage and pure AC voltage. The results can provide the basis experimental data for condition assessment of converter transformer by using the method of online monitoring of dissolved gas in oil.\",\"PeriodicalId\":393969,\"journal\":{\"name\":\"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2013.6748161\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2013.6748161","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

油中溶解气体在线监测是变压器状态评估的有效方法之一。与电力变压器相比,换流变压器阀侧绕组在换流过程中承受脉动电压。本文研究了不同于单独交流电压下的油绝缘在脉动电压下的产气特性。设计了三种放电模型,并进行了大量局部放电实验,研究了脉动电压下油中溶解气体的变化特性。分析了不同放电模式下油中气体浓度在s过程中的增量,脉动电压下的实验结果表明,在脉动电压和纯交流电压下,溶解气体组分含量有明显差异。研究结果可为采用油中溶解气体在线监测方法进行换流变压器状态评估提供基础实验数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Gas generation properties of oil-paper insulation under pulsating voltage
On-line monitoring of dissolved gas in oil is one of effective methods of condition assessment of transformers. Compared with the power transformer, valve side windings of converter transformer withstand pulsating voltage during the converter process. This paper presents gas generation properties of oil insulation under pulsating voltages, which are different from those under individual AC voltage. Three discharge models were designed and lots of partial discharge experiments were carried out to research the variation characteristics of dissolved gases in oil under pulsating voltages. The increment of gases concentration in oil during the progress of s of different discharge models were analyzed, the experiment results under pulsating voltages showed that the dissolved gas component content was obviously different under pulsating voltage and pure AC voltage. The results can provide the basis experimental data for condition assessment of converter transformer by using the method of online monitoring of dissolved gas in oil.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信