采用数字波束形成和自主通道控制的实时相控阵成像

M. O’Donnell, W. Engeler, J. T. Pedicone, Ahmad M. Itani, S. Noujaim, R. Dunki-Jacobs, W. Leue, C. Chalek, L. Smith, J. Piel, R. L. Harris, K. Welles, W. Hinrichs
{"title":"采用数字波束形成和自主通道控制的实时相控阵成像","authors":"M. O’Donnell, W. Engeler, J. T. Pedicone, Ahmad M. Itani, S. Noujaim, R. Dunki-Jacobs, W. Leue, C. Chalek, L. Smith, J. Piel, R. L. Harris, K. Welles, W. Hinrichs","doi":"10.1109/ULTSYM.1990.171616","DOIUrl":null,"url":null,"abstract":"The authors designed and constructed a real-time phased-array imaging system for medical applications based on the principles of digital beam formation and autonomous channel control. The system is capable of high-precision steering, dynamic apodization, dynamic focusing, and highly accurate beamforming using sampling rates close to the Nyquist rate over the medical diagnostic frequency range. All controls and signal processing needed for a single channel of the array imager have been integrated into a single custom VLSI circuit. The authors describe the basic principles embodied in this chip.<<ETX>>","PeriodicalId":412254,"journal":{"name":"IEEE Symposium on Ultrasonics","volume":"29 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1990-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"76","resultStr":"{\"title\":\"Real-time phased array imaging using digital beam forming and autonomous channel control\",\"authors\":\"M. O’Donnell, W. Engeler, J. T. Pedicone, Ahmad M. Itani, S. Noujaim, R. Dunki-Jacobs, W. Leue, C. Chalek, L. Smith, J. Piel, R. L. Harris, K. Welles, W. Hinrichs\",\"doi\":\"10.1109/ULTSYM.1990.171616\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors designed and constructed a real-time phased-array imaging system for medical applications based on the principles of digital beam formation and autonomous channel control. The system is capable of high-precision steering, dynamic apodization, dynamic focusing, and highly accurate beamforming using sampling rates close to the Nyquist rate over the medical diagnostic frequency range. All controls and signal processing needed for a single channel of the array imager have been integrated into a single custom VLSI circuit. The authors describe the basic principles embodied in this chip.<<ETX>>\",\"PeriodicalId\":412254,\"journal\":{\"name\":\"IEEE Symposium on Ultrasonics\",\"volume\":\"29 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-12-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"76\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Symposium on Ultrasonics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ULTSYM.1990.171616\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Symposium on Ultrasonics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ULTSYM.1990.171616","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 76

摘要

基于数字波束形成和自主通道控制的原理,设计并构建了一种实时医学相控阵成像系统。该系统能够在医疗诊断频率范围内使用接近奈奎斯特率的采样率进行高精度转向、动态取证、动态聚焦和高精度波束形成。阵列成像仪的单个通道所需的所有控制和信号处理已集成到单个定制VLSI电路中。作者描述了该芯片的基本原理
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Real-time phased array imaging using digital beam forming and autonomous channel control
The authors designed and constructed a real-time phased-array imaging system for medical applications based on the principles of digital beam formation and autonomous channel control. The system is capable of high-precision steering, dynamic apodization, dynamic focusing, and highly accurate beamforming using sampling rates close to the Nyquist rate over the medical diagnostic frequency range. All controls and signal processing needed for a single channel of the array imager have been integrated into a single custom VLSI circuit. The authors describe the basic principles embodied in this chip.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信