结构基础隔振磁流变阻尼器的模糊半主动控制

Han Wang, H. Malki, G. Song
{"title":"结构基础隔振磁流变阻尼器的模糊半主动控制","authors":"Han Wang, H. Malki, G. Song","doi":"10.1109/FUZZY.2009.5277267","DOIUrl":null,"url":null,"abstract":"This paper presents four types of semi-active control on Magnetorheological (MR) Damper in an experimental base isolation structure model with three degree-of-freedom. The semi-active control methods include proportional-derivative (PD) control, and three fuzzy control methods: rule-based fuzzy logic control, auto-tuning fuzzy PD control, and discrete fuzzy PD control. The main purpose is to compare the response effect between passive control methods and semi-active control methods, and also compare within semi-active controls. The results of both passive controls and semi-active controls in experiments are presented. From the results, semi-active controls are shown more adaptive than passive control for this model when the earthquake type is unknown. Moreover, auto-tuning fuzzy PD control is proved to have relatively best performance among all control methods.","PeriodicalId":117895,"journal":{"name":"2009 IEEE International Conference on Fuzzy Systems","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2009-10-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Fuzzy semi-active control of MR damper for structural base isolation\",\"authors\":\"Han Wang, H. Malki, G. Song\",\"doi\":\"10.1109/FUZZY.2009.5277267\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents four types of semi-active control on Magnetorheological (MR) Damper in an experimental base isolation structure model with three degree-of-freedom. The semi-active control methods include proportional-derivative (PD) control, and three fuzzy control methods: rule-based fuzzy logic control, auto-tuning fuzzy PD control, and discrete fuzzy PD control. The main purpose is to compare the response effect between passive control methods and semi-active control methods, and also compare within semi-active controls. The results of both passive controls and semi-active controls in experiments are presented. From the results, semi-active controls are shown more adaptive than passive control for this model when the earthquake type is unknown. Moreover, auto-tuning fuzzy PD control is proved to have relatively best performance among all control methods.\",\"PeriodicalId\":117895,\"journal\":{\"name\":\"2009 IEEE International Conference on Fuzzy Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-10-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 IEEE International Conference on Fuzzy Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/FUZZY.2009.5277267\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 IEEE International Conference on Fuzzy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/FUZZY.2009.5277267","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文在一个三自由度实验基座隔振结构模型中,对磁流变阻尼器进行了四种半主动控制。半主动控制方法包括比例导数控制(PD)和三种模糊控制方法:基于规则的模糊逻辑控制、自整定模糊PD控制和离散模糊PD控制。主要目的是比较被动控制方法和半主动控制方法之间的响应效果,以及半主动控制内的比较。给出了被动控制和半主动控制的实验结果。结果表明,当地震类型未知时,半主动控制比被动控制具有更强的自适应能力。在所有控制方法中,自整定模糊PD控制的性能相对较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fuzzy semi-active control of MR damper for structural base isolation
This paper presents four types of semi-active control on Magnetorheological (MR) Damper in an experimental base isolation structure model with three degree-of-freedom. The semi-active control methods include proportional-derivative (PD) control, and three fuzzy control methods: rule-based fuzzy logic control, auto-tuning fuzzy PD control, and discrete fuzzy PD control. The main purpose is to compare the response effect between passive control methods and semi-active control methods, and also compare within semi-active controls. The results of both passive controls and semi-active controls in experiments are presented. From the results, semi-active controls are shown more adaptive than passive control for this model when the earthquake type is unknown. Moreover, auto-tuning fuzzy PD control is proved to have relatively best performance among all control methods.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信