M. Marcacci, R. Soavi, I. Loreti, L. Bragonzoni, F. Iacono, A. Visani
{"title":"轴间假体半轴承之间的微运动:一个伦线立体摄影测量分析。","authors":"M. Marcacci, R. Soavi, I. Loreti, L. Bragonzoni, F. Iacono, A. Visani","doi":"10.1054/ARTH.2001.25560","DOIUrl":null,"url":null,"abstract":"We assessed the migration and movement between the half-bearings of the Interax prosthesis in 18 patients using roentgen stereophotogrammetric analysis (RSA). This study showed movements of the tibial component even in successful knee arthroplasty: 17 prostheses migrated only initially and remained stable after 1 year, whereas 1 prosthesis migrated consistently throughout 3-year follow-up. RSA revealed no or minimal displacement between the half-bearings until the 4-year follow-up, confirming that their fixation to the baseplate was adequate. In the case of loosening, a rotation about the longitudinal axis of 1.3 degrees and a medial-lateral translation of 0.5 mm was observed between the half-bearings. Cold flow was revealed by RSA in the posterior region of the medial half-bearing.","PeriodicalId":280050,"journal":{"name":"The Journal of arthroplasty","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Micromotion between the half bearings in the interax prosthesis: a roentgen stereophotogrammetric analysis.\",\"authors\":\"M. Marcacci, R. Soavi, I. Loreti, L. Bragonzoni, F. Iacono, A. Visani\",\"doi\":\"10.1054/ARTH.2001.25560\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We assessed the migration and movement between the half-bearings of the Interax prosthesis in 18 patients using roentgen stereophotogrammetric analysis (RSA). This study showed movements of the tibial component even in successful knee arthroplasty: 17 prostheses migrated only initially and remained stable after 1 year, whereas 1 prosthesis migrated consistently throughout 3-year follow-up. RSA revealed no or minimal displacement between the half-bearings until the 4-year follow-up, confirming that their fixation to the baseplate was adequate. In the case of loosening, a rotation about the longitudinal axis of 1.3 degrees and a medial-lateral translation of 0.5 mm was observed between the half-bearings. Cold flow was revealed by RSA in the posterior region of the medial half-bearing.\",\"PeriodicalId\":280050,\"journal\":{\"name\":\"The Journal of arthroplasty\",\"volume\":\"16 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of arthroplasty\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1054/ARTH.2001.25560\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of arthroplasty","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1054/ARTH.2001.25560","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Micromotion between the half bearings in the interax prosthesis: a roentgen stereophotogrammetric analysis.
We assessed the migration and movement between the half-bearings of the Interax prosthesis in 18 patients using roentgen stereophotogrammetric analysis (RSA). This study showed movements of the tibial component even in successful knee arthroplasty: 17 prostheses migrated only initially and remained stable after 1 year, whereas 1 prosthesis migrated consistently throughout 3-year follow-up. RSA revealed no or minimal displacement between the half-bearings until the 4-year follow-up, confirming that their fixation to the baseplate was adequate. In the case of loosening, a rotation about the longitudinal axis of 1.3 degrees and a medial-lateral translation of 0.5 mm was observed between the half-bearings. Cold flow was revealed by RSA in the posterior region of the medial half-bearing.