{"title":"A /spl plusmn/150 MVAr STATCOM用于东北公用事业公司的Glenbrook变电站","authors":"A. Scarfone, B. Oberlin, J.P. Di Luca, D. J. Hanson, C. Horwill","doi":"10.1109/PES.2003.1267440","DOIUrl":null,"url":null,"abstract":"Northeast Utilities (NU), located in Hartford, Connecticut, is preparing to install a new flexible AC transmission system (FACTS) voltage sourced controller at its Glenbrook 115 kV substation in Stamford, Connecticut. Glenbrook is located within the Norwalk-Stanford area of southwestern Connecticut. In the summer of 2000, a low voltage event occurred in the area. Voltage recovery took approximately 8 to 10 seconds. Transmission planning studies have confirmed that the Norwalk-Stamford area is susceptible to a possible voltage collapse during certain contingencies. To mitigate similar low voltage conditions, three possible solutions were investigated by NU; install fixed shunt capacitors, upgrade existing overhead lines to a higher voltage level, and install a FACTS device. Of the three alternatives investigated, NU concluded that a FACTS device was the only near term viable option. The function of the STATCOM and its location on the system are discussed. Reasons for the finally chosen configuration are give, the choice being made to maximize availability, even following a circuit breaker failure or bus fault. The overall design of the STATCOM and its layout are described, together with a description of the chain-link voltages sourced converter.","PeriodicalId":131986,"journal":{"name":"2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491)","volume":"77 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"A /spl plusmn/150 MVAr STATCOM for Northeast Utilities' Glenbrook substation\",\"authors\":\"A. Scarfone, B. Oberlin, J.P. Di Luca, D. J. Hanson, C. Horwill\",\"doi\":\"10.1109/PES.2003.1267440\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Northeast Utilities (NU), located in Hartford, Connecticut, is preparing to install a new flexible AC transmission system (FACTS) voltage sourced controller at its Glenbrook 115 kV substation in Stamford, Connecticut. Glenbrook is located within the Norwalk-Stanford area of southwestern Connecticut. In the summer of 2000, a low voltage event occurred in the area. Voltage recovery took approximately 8 to 10 seconds. Transmission planning studies have confirmed that the Norwalk-Stamford area is susceptible to a possible voltage collapse during certain contingencies. To mitigate similar low voltage conditions, three possible solutions were investigated by NU; install fixed shunt capacitors, upgrade existing overhead lines to a higher voltage level, and install a FACTS device. Of the three alternatives investigated, NU concluded that a FACTS device was the only near term viable option. The function of the STATCOM and its location on the system are discussed. Reasons for the finally chosen configuration are give, the choice being made to maximize availability, even following a circuit breaker failure or bus fault. The overall design of the STATCOM and its layout are described, together with a description of the chain-link voltages sourced converter.\",\"PeriodicalId\":131986,\"journal\":{\"name\":\"2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491)\",\"volume\":\"77 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-07-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PES.2003.1267440\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PES.2003.1267440","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

位于康涅狄格州哈特福德的东北公用事业公司(NU)正准备在其位于康涅狄格州斯坦福德的Glenbrook 115千伏变电站安装一个新的柔性交流输电系统(FACTS)电压源控制器。格伦布鲁克位于康涅狄格州西南部的诺沃克-斯坦福地区。2000年夏天,该地区发生了一次低电压事件。电压恢复大约需要8到10秒。输电规划研究已经证实,在某些突发事件中,诺沃克-斯坦福德地区容易受到可能的电压崩溃的影响。为了缓解类似的低电压情况,NU研究了三种可能的解决方案;安装固定并联电容器,将现有架空线路升级到更高的电压水平,并安装FACTS设备。在调查的三个备选方案中,NU得出结论,FACTS设备是近期唯一可行的选择。讨论了STATCOM的功能及其在系统中的位置。给出了最终选择配置的原因,即使在断路器故障或总线故障之后,也要做出最大可用性的选择。介绍了STATCOM的总体设计及其布局,并对链式电压源变换器进行了描述。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A /spl plusmn/150 MVAr STATCOM for Northeast Utilities' Glenbrook substation
Northeast Utilities (NU), located in Hartford, Connecticut, is preparing to install a new flexible AC transmission system (FACTS) voltage sourced controller at its Glenbrook 115 kV substation in Stamford, Connecticut. Glenbrook is located within the Norwalk-Stanford area of southwestern Connecticut. In the summer of 2000, a low voltage event occurred in the area. Voltage recovery took approximately 8 to 10 seconds. Transmission planning studies have confirmed that the Norwalk-Stamford area is susceptible to a possible voltage collapse during certain contingencies. To mitigate similar low voltage conditions, three possible solutions were investigated by NU; install fixed shunt capacitors, upgrade existing overhead lines to a higher voltage level, and install a FACTS device. Of the three alternatives investigated, NU concluded that a FACTS device was the only near term viable option. The function of the STATCOM and its location on the system are discussed. Reasons for the finally chosen configuration are give, the choice being made to maximize availability, even following a circuit breaker failure or bus fault. The overall design of the STATCOM and its layout are described, together with a description of the chain-link voltages sourced converter.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信