相对湿度对线对平面静电除尘器集尘效率的影响

H. Nouri, Y. Zebboudj, N. Zouzou, E. Moreau, L. Dascalescu
{"title":"相对湿度对线对平面静电除尘器集尘效率的影响","authors":"H. Nouri, Y. Zebboudj, N. Zouzou, E. Moreau, L. Dascalescu","doi":"10.1109/IAS.2010.5615948","DOIUrl":null,"url":null,"abstract":"This paper aims to analyse the influence of the atmospheric relative humidity level (RH) on the collection efficiency of a wire-to-plane electrostatic precipitator (WP-ESP). The experiments were performed with incense smoke particles having a mean size of about 0.28 µm. An aerosol spectrometer was employed for characterizing the size distribution of these particles at the outlet of the ESP. Then, the total and fractional collection efficiencies were estimated for different relative humidity levels ranging from 40 to 70 %. Various DC applied voltages in the case of positive and negative polarities have been under consideration. For given atmospheric conditions, the results obtained with the aerosol spectrometer show that the performances of the ESP increases with the applied voltage (range: 10 to 40 kV) and the particle diameter (range: 0.2 to 0.7 µm). The collection efficiency is higher at increased RH. The negative corona discharge is overall more effective than the positive one. However, the difference between the two polarities becomes minor at high RH.","PeriodicalId":317643,"journal":{"name":"2010 IEEE Industry Applications Society Annual Meeting","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Effect of Relative Humidity on the Collection Efficiency of a Wire-To-Plane Electrostatic Precipitator\",\"authors\":\"H. Nouri, Y. Zebboudj, N. Zouzou, E. Moreau, L. Dascalescu\",\"doi\":\"10.1109/IAS.2010.5615948\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper aims to analyse the influence of the atmospheric relative humidity level (RH) on the collection efficiency of a wire-to-plane electrostatic precipitator (WP-ESP). The experiments were performed with incense smoke particles having a mean size of about 0.28 µm. An aerosol spectrometer was employed for characterizing the size distribution of these particles at the outlet of the ESP. Then, the total and fractional collection efficiencies were estimated for different relative humidity levels ranging from 40 to 70 %. Various DC applied voltages in the case of positive and negative polarities have been under consideration. For given atmospheric conditions, the results obtained with the aerosol spectrometer show that the performances of the ESP increases with the applied voltage (range: 10 to 40 kV) and the particle diameter (range: 0.2 to 0.7 µm). The collection efficiency is higher at increased RH. The negative corona discharge is overall more effective than the positive one. However, the difference between the two polarities becomes minor at high RH.\",\"PeriodicalId\":317643,\"journal\":{\"name\":\"2010 IEEE Industry Applications Society Annual Meeting\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE Industry Applications Society Annual Meeting\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IAS.2010.5615948\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2010.5615948","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

本文旨在分析大气相对湿度对线对平面静电除尘器(WP-ESP)集尘效率的影响。实验采用平均尺寸约为0.28µm的香烟颗粒进行。利用气溶胶光谱仪对ESP出口的颗粒大小分布进行了表征。然后,在相对湿度为40%至70%的不同条件下,估计了总收集效率和部分收集效率。在正极性和负极性的情况下,考虑了各种直流施加电压。在一定的大气条件下,气溶胶谱仪的结果表明,ESP的性能随施加电压(10 ~ 40 kV)和粒子直径(0.2 ~ 0.7µm)的增大而增大。在较高的RH下,收集效率更高。负电晕放电总体上比正电晕放电更有效。然而,在高相对湿度下,两个极性之间的差异变得很小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of Relative Humidity on the Collection Efficiency of a Wire-To-Plane Electrostatic Precipitator
This paper aims to analyse the influence of the atmospheric relative humidity level (RH) on the collection efficiency of a wire-to-plane electrostatic precipitator (WP-ESP). The experiments were performed with incense smoke particles having a mean size of about 0.28 µm. An aerosol spectrometer was employed for characterizing the size distribution of these particles at the outlet of the ESP. Then, the total and fractional collection efficiencies were estimated for different relative humidity levels ranging from 40 to 70 %. Various DC applied voltages in the case of positive and negative polarities have been under consideration. For given atmospheric conditions, the results obtained with the aerosol spectrometer show that the performances of the ESP increases with the applied voltage (range: 10 to 40 kV) and the particle diameter (range: 0.2 to 0.7 µm). The collection efficiency is higher at increased RH. The negative corona discharge is overall more effective than the positive one. However, the difference between the two polarities becomes minor at high RH.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信