{"title":"探头传声器频率特性的理论研究与实验","authors":"K. Yunoki, Y. Tanaka, T. Yoshino, H. Hirakawa","doi":"10.1109/SICE.1999.788593","DOIUrl":null,"url":null,"abstract":"A probe microphone has a thin, empty and long probe tube. Therefore, frequency characteristics of a probe microphone are not good. In this paper, we analyze a probe microphone constructed by a probe, a spacer and a regular microphone. In this microphone, the sound wave is attenuated by viscosity of air. So, sound solution is given with the attenuation constant /spl delta/ and the phase constant K. As a result, frequency characteristics of a probe microphone were obtained for the size of the probe tube, /spl delta/ and K. In the experiment, applying a white noise or a rectangular signal to the speaker,sound from the probe microphone was compared with that of the regular microphone. Experimental results agreed well with the theoretical ones.","PeriodicalId":103164,"journal":{"name":"SICE '99. Proceedings of the 38th SICE Annual Conference. International Session Papers (IEEE Cat. No.99TH8456)","volume":"132 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Theoretical study and experiment on frequency characteristics of a probe microphone\",\"authors\":\"K. Yunoki, Y. Tanaka, T. Yoshino, H. Hirakawa\",\"doi\":\"10.1109/SICE.1999.788593\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A probe microphone has a thin, empty and long probe tube. Therefore, frequency characteristics of a probe microphone are not good. In this paper, we analyze a probe microphone constructed by a probe, a spacer and a regular microphone. In this microphone, the sound wave is attenuated by viscosity of air. So, sound solution is given with the attenuation constant /spl delta/ and the phase constant K. As a result, frequency characteristics of a probe microphone were obtained for the size of the probe tube, /spl delta/ and K. In the experiment, applying a white noise or a rectangular signal to the speaker,sound from the probe microphone was compared with that of the regular microphone. Experimental results agreed well with the theoretical ones.\",\"PeriodicalId\":103164,\"journal\":{\"name\":\"SICE '99. Proceedings of the 38th SICE Annual Conference. International Session Papers (IEEE Cat. No.99TH8456)\",\"volume\":\"132 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-07-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SICE '99. Proceedings of the 38th SICE Annual Conference. International Session Papers (IEEE Cat. No.99TH8456)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SICE.1999.788593\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SICE '99. Proceedings of the 38th SICE Annual Conference. International Session Papers (IEEE Cat. No.99TH8456)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SICE.1999.788593","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

探头麦克风有一个细的、空的、长的探头管。因此,探头传声器的频率特性不是很好。本文分析了一种由探针、间隔器和普通传声器组成的探针传声器。在这个麦克风里,声波被空气的粘性减弱了。因此,给出了衰减常数/spl delta/和相位常数k的声音解,从而得到了探头管尺寸/spl delta/和k的频率特性。在实验中,对扬声器施加白噪声或矩形信号,将探头麦克风发出的声音与普通麦克风的声音进行了比较。实验结果与理论结果吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Theoretical study and experiment on frequency characteristics of a probe microphone
A probe microphone has a thin, empty and long probe tube. Therefore, frequency characteristics of a probe microphone are not good. In this paper, we analyze a probe microphone constructed by a probe, a spacer and a regular microphone. In this microphone, the sound wave is attenuated by viscosity of air. So, sound solution is given with the attenuation constant /spl delta/ and the phase constant K. As a result, frequency characteristics of a probe microphone were obtained for the size of the probe tube, /spl delta/ and K. In the experiment, applying a white noise or a rectangular signal to the speaker,sound from the probe microphone was compared with that of the regular microphone. Experimental results agreed well with the theoretical ones.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信