电站用钢性能的非接触式电磁测量

N. Karimian, W. Yin, J. Liu, X. Hao, M. Strangwood, C. Davis, A. Peyton
{"title":"电站用钢性能的非接触式电磁测量","authors":"N. Karimian, W. Yin, J. Liu, X. Hao, M. Strangwood, C. Davis, A. Peyton","doi":"10.1109/I2MTC.2013.6555679","DOIUrl":null,"url":null,"abstract":"Analysis of the electromagnetic properties of power station steels, measured using a non-contact EM sensor, is of significance as such properties are indicative of the microstructure of the material. In this paper, we present the measurement of cylindrical power station steel samples (namely P91 and P9 grades) in different conditions. Initially the B-H curves of these steel samples were measured. Then printed circuit board (PCB) coil integrated sensors were used to measure the incremental permeability. Analytical and numerical methods (Finite Elements Methods) were employed to calculate the sensor response of these samples. Experimental results were obtained for a range of samples and their electromagnetic properties inferred by fitting finite element models to the measured results.","PeriodicalId":432388,"journal":{"name":"2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Non-contact EM measurement of the properties of power station steels taken from service\",\"authors\":\"N. Karimian, W. Yin, J. Liu, X. Hao, M. Strangwood, C. Davis, A. Peyton\",\"doi\":\"10.1109/I2MTC.2013.6555679\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Analysis of the electromagnetic properties of power station steels, measured using a non-contact EM sensor, is of significance as such properties are indicative of the microstructure of the material. In this paper, we present the measurement of cylindrical power station steel samples (namely P91 and P9 grades) in different conditions. Initially the B-H curves of these steel samples were measured. Then printed circuit board (PCB) coil integrated sensors were used to measure the incremental permeability. Analytical and numerical methods (Finite Elements Methods) were employed to calculate the sensor response of these samples. Experimental results were obtained for a range of samples and their electromagnetic properties inferred by fitting finite element models to the measured results.\",\"PeriodicalId\":432388,\"journal\":{\"name\":\"2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-05-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/I2MTC.2013.6555679\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/I2MTC.2013.6555679","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

使用非接触式电磁传感器对电站钢的电磁性能进行分析是有意义的,因为这些性能表明了材料的微观结构。在本文中,我们提出了圆柱形电站钢样品(即P91和P9等级)在不同条件下的测量。首先测量了这些钢样品的B-H曲线。然后采用印刷电路板线圈集成传感器测量增量磁导率。采用解析和数值方法(有限元法)计算了这些样品的传感器响应。得到了一系列样品的实验结果,并通过有限元模型与测量结果拟合推断了样品的电磁特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Non-contact EM measurement of the properties of power station steels taken from service
Analysis of the electromagnetic properties of power station steels, measured using a non-contact EM sensor, is of significance as such properties are indicative of the microstructure of the material. In this paper, we present the measurement of cylindrical power station steel samples (namely P91 and P9 grades) in different conditions. Initially the B-H curves of these steel samples were measured. Then printed circuit board (PCB) coil integrated sensors were used to measure the incremental permeability. Analytical and numerical methods (Finite Elements Methods) were employed to calculate the sensor response of these samples. Experimental results were obtained for a range of samples and their electromagnetic properties inferred by fitting finite element models to the measured results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信