{"title":"多电平变频器传导电磁干扰的抑制技术","authors":"A. Kempski, R. Smoleński, E. Kot","doi":"10.1109/CPE.2005.1547570","DOIUrl":null,"url":null,"abstract":"In this paper the method of passive compensa- tion of a common mode (CM) voltage in a multilevel inverter drive system by means of the filter having sinusoidal output voltages and zero CM voltage has been presented. The main problem with the application of this solution is a magnetic saturation of the CM choke. There have been presented simu- lation and experimental results showing that the problem with magnetic saturation become less important in multilevel in- verter drives, thus permitting a reduction of size, weight and cost of inductive components of filters in such drives.","PeriodicalId":142625,"journal":{"name":"IEEE Compatibility in Power Electronics, 2005.","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Mitigation techniques of conducted emi in multilevel inverter drives\",\"authors\":\"A. Kempski, R. Smoleński, E. Kot\",\"doi\":\"10.1109/CPE.2005.1547570\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper the method of passive compensa- tion of a common mode (CM) voltage in a multilevel inverter drive system by means of the filter having sinusoidal output voltages and zero CM voltage has been presented. The main problem with the application of this solution is a magnetic saturation of the CM choke. There have been presented simu- lation and experimental results showing that the problem with magnetic saturation become less important in multilevel in- verter drives, thus permitting a reduction of size, weight and cost of inductive components of filters in such drives.\",\"PeriodicalId\":142625,\"journal\":{\"name\":\"IEEE Compatibility in Power Electronics, 2005.\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Compatibility in Power Electronics, 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPE.2005.1547570\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Compatibility in Power Electronics, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPE.2005.1547570","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Mitigation techniques of conducted emi in multilevel inverter drives
In this paper the method of passive compensa- tion of a common mode (CM) voltage in a multilevel inverter drive system by means of the filter having sinusoidal output voltages and zero CM voltage has been presented. The main problem with the application of this solution is a magnetic saturation of the CM choke. There have been presented simu- lation and experimental results showing that the problem with magnetic saturation become less important in multilevel in- verter drives, thus permitting a reduction of size, weight and cost of inductive components of filters in such drives.