Wei Wang, C.R. Li, Z. Tang, Zhili Li, Yansheng Ding
{"title":"电力变压器超高频局部放电在线监测系统","authors":"Wei Wang, C.R. Li, Z. Tang, Zhili Li, Yansheng Ding","doi":"10.1109/ELINSL.2004.1380443","DOIUrl":null,"url":null,"abstract":"An online UHF PD monitoring system for power transformers has been designed and installed in a 120MVA/220kV power transformer in-service in Henan province of China. The hardware and software of the system are described in detail in this paper. The onsite results show that the online monitoring system has superior performance compared to conventional PD detection system.","PeriodicalId":342687,"journal":{"name":"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"An online UHF PD monitoring system for power transformers\",\"authors\":\"Wei Wang, C.R. Li, Z. Tang, Zhili Li, Yansheng Ding\",\"doi\":\"10.1109/ELINSL.2004.1380443\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An online UHF PD monitoring system for power transformers has been designed and installed in a 120MVA/220kV power transformer in-service in Henan province of China. The hardware and software of the system are described in detail in this paper. The onsite results show that the online monitoring system has superior performance compared to conventional PD detection system.\",\"PeriodicalId\":342687,\"journal\":{\"name\":\"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2004.1380443\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2004.1380443","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
An online UHF PD monitoring system for power transformers
An online UHF PD monitoring system for power transformers has been designed and installed in a 120MVA/220kV power transformer in-service in Henan province of China. The hardware and software of the system are described in detail in this paper. The onsite results show that the online monitoring system has superior performance compared to conventional PD detection system.