J. Urrea-Quintero, N. Muñoz-Galeano, Daniel A. Cuervo-Sanchez
{"title":"基于非线性动力学模型的电力电子变流器可控性验证设计程序","authors":"J. Urrea-Quintero, N. Muñoz-Galeano, Daniel A. Cuervo-Sanchez","doi":"10.1109/PEPQA.2017.7981688","DOIUrl":null,"url":null,"abstract":"In this work a design procedure of Power Electronic Converters (PECs) is proposed, which is based on system knowledge and systems theory. The proposed design procedure is composed of 4 stages and 10 steps and it allows to obtain all PEC parameters and its control structure such that established system operating requirements are satisfied. In this proposed design procedure, system controllability is tested based on set theory in control. The main achievement of this design procedure is to allow the PEC design to take into account its inherent dynamical nature, with verified controllability, but without fixing any control structure.","PeriodicalId":256426,"journal":{"name":"2017 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)","volume":"37 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A procedure for power electronic converters design with controllability verification based on the nonlinear dynamical model\",\"authors\":\"J. Urrea-Quintero, N. Muñoz-Galeano, Daniel A. Cuervo-Sanchez\",\"doi\":\"10.1109/PEPQA.2017.7981688\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work a design procedure of Power Electronic Converters (PECs) is proposed, which is based on system knowledge and systems theory. The proposed design procedure is composed of 4 stages and 10 steps and it allows to obtain all PEC parameters and its control structure such that established system operating requirements are satisfied. In this proposed design procedure, system controllability is tested based on set theory in control. The main achievement of this design procedure is to allow the PEC design to take into account its inherent dynamical nature, with verified controllability, but without fixing any control structure.\",\"PeriodicalId\":256426,\"journal\":{\"name\":\"2017 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)\",\"volume\":\"37 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEPQA.2017.7981688\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEPQA.2017.7981688","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A procedure for power electronic converters design with controllability verification based on the nonlinear dynamical model
In this work a design procedure of Power Electronic Converters (PECs) is proposed, which is based on system knowledge and systems theory. The proposed design procedure is composed of 4 stages and 10 steps and it allows to obtain all PEC parameters and its control structure such that established system operating requirements are satisfied. In this proposed design procedure, system controllability is tested based on set theory in control. The main achievement of this design procedure is to allow the PEC design to take into account its inherent dynamical nature, with verified controllability, but without fixing any control structure.