{"title":"超声造影剂的使用","authors":"K. Shahnazi, M. Fox","doi":"10.1109/NEBC.1994.305167","DOIUrl":null,"url":null,"abstract":"By using Albunex, a recently developed ultrasound contrast agent, a clear Doppler ultrasound signal, and a B-mode image of the flow stream has been obtained. For the Doppler signal, a Hokanson Doppler unit with 5 MHz transducer was used, and for the image of the flow stream, a GE imager with 7.5 Mhz transducer was used. In this experiment, a straight 1:1000 dilution for Albunex (Molecular Biosystems Inc., San Diego, CA) was prepared. For the flow stream, a 1 mm groove in a plexiglass phantom was prepared. The Doppler signal, and the image obtained show a clear distinction between contrast agents and water. Therefore, by using an ultrasound contrast agent, flow and flow direction can be visualized using a conventional B-mode imager.<<ETX>>","PeriodicalId":117140,"journal":{"name":"Proceedings of 1994 20th Annual Northeast Bioengineering Conference","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"Use of contrast agents in ultrasound\",\"authors\":\"K. Shahnazi, M. Fox\",\"doi\":\"10.1109/NEBC.1994.305167\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"By using Albunex, a recently developed ultrasound contrast agent, a clear Doppler ultrasound signal, and a B-mode image of the flow stream has been obtained. For the Doppler signal, a Hokanson Doppler unit with 5 MHz transducer was used, and for the image of the flow stream, a GE imager with 7.5 Mhz transducer was used. In this experiment, a straight 1:1000 dilution for Albunex (Molecular Biosystems Inc., San Diego, CA) was prepared. For the flow stream, a 1 mm groove in a plexiglass phantom was prepared. The Doppler signal, and the image obtained show a clear distinction between contrast agents and water. Therefore, by using an ultrasound contrast agent, flow and flow direction can be visualized using a conventional B-mode imager.<<ETX>>\",\"PeriodicalId\":117140,\"journal\":{\"name\":\"Proceedings of 1994 20th Annual Northeast Bioengineering Conference\",\"volume\":\"54 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-03-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 1994 20th Annual Northeast Bioengineering Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEBC.1994.305167\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 1994 20th Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBC.1994.305167","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18
摘要
通过使用最新开发的超声造影剂Albunex,获得了清晰的多普勒超声信号和血流的b型图像。对于多普勒信号,使用带有5 MHz换能器的Hokanson多普勒单元,对于流的图像,使用带有7.5 MHz换能器的GE成像仪。在本实验中,制备了Albunex (Molecular Biosystems Inc., San Diego, CA)的1:1000稀释液。在有机玻璃模体上制备了1 mm的凹槽。多普勒信号和图像显示造影剂和水的明显区别。因此,通过使用超声造影剂,可以使用传统的b型成像仪可视化血流和血流方向。
By using Albunex, a recently developed ultrasound contrast agent, a clear Doppler ultrasound signal, and a B-mode image of the flow stream has been obtained. For the Doppler signal, a Hokanson Doppler unit with 5 MHz transducer was used, and for the image of the flow stream, a GE imager with 7.5 Mhz transducer was used. In this experiment, a straight 1:1000 dilution for Albunex (Molecular Biosystems Inc., San Diego, CA) was prepared. For the flow stream, a 1 mm groove in a plexiglass phantom was prepared. The Doppler signal, and the image obtained show a clear distinction between contrast agents and water. Therefore, by using an ultrasound contrast agent, flow and flow direction can be visualized using a conventional B-mode imager.<>