静脉曲张管理压力优化系统

Rithika K, S. Saranya, Chandramouli K, A. M
{"title":"静脉曲张管理压力优化系统","authors":"Rithika K, S. Saranya, Chandramouli K, A. M","doi":"10.1109/TENSYMP55890.2023.10223642","DOIUrl":null,"url":null,"abstract":"Veins have one way valves inside them that open and close to keep the blood flowing towards the heart. Varicose veins represent a condition where the weak or damaged valves in the veins can cause blood to pool and even flow backwards. It is most common in pregnant women and the elderly. Compression therapy is an established treatment for varicose veins, where the applied pressure has to be in specific ranges in order to have an effective treatment. No method currently exists for monitoring the pressure applied in the leg while tying the compression bandage on the affected leg. Improper application of compression bandage can be ineffective or can cause issues such as skin irritation, discoloration, dent in skin and can also cause necrosis. This paper aims to provide a pressure indicating system with Force sensing resistor (FSR) and Light emitting diodes (LEDs) integrated with compression bandage for pressure optimization and management of varicose veins. The effectiveness of the pressure indicating system is validated by measuring the subject's vein length within a span of four weeks.","PeriodicalId":314726,"journal":{"name":"2023 IEEE Region 10 Symposium (TENSYMP)","volume":"226 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Pressure optimization system for Varicose Veins management\",\"authors\":\"Rithika K, S. Saranya, Chandramouli K, A. M\",\"doi\":\"10.1109/TENSYMP55890.2023.10223642\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Veins have one way valves inside them that open and close to keep the blood flowing towards the heart. Varicose veins represent a condition where the weak or damaged valves in the veins can cause blood to pool and even flow backwards. It is most common in pregnant women and the elderly. Compression therapy is an established treatment for varicose veins, where the applied pressure has to be in specific ranges in order to have an effective treatment. No method currently exists for monitoring the pressure applied in the leg while tying the compression bandage on the affected leg. Improper application of compression bandage can be ineffective or can cause issues such as skin irritation, discoloration, dent in skin and can also cause necrosis. This paper aims to provide a pressure indicating system with Force sensing resistor (FSR) and Light emitting diodes (LEDs) integrated with compression bandage for pressure optimization and management of varicose veins. The effectiveness of the pressure indicating system is validated by measuring the subject's vein length within a span of four weeks.\",\"PeriodicalId\":314726,\"journal\":{\"name\":\"2023 IEEE Region 10 Symposium (TENSYMP)\",\"volume\":\"226 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 IEEE Region 10 Symposium (TENSYMP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TENSYMP55890.2023.10223642\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE Region 10 Symposium (TENSYMP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TENSYMP55890.2023.10223642","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

静脉内部有单向阀,这些单向阀可以打开和关闭以保持血液流向心脏。静脉曲张是一种情况,静脉中的瓣膜脆弱或受损,会导致血液淤积甚至倒流。最常见于孕妇和老年人。压迫疗法是一种治疗静脉曲张的成熟疗法,为了有效治疗,施加的压力必须在特定的范围内。目前还没有一种方法可以监测在受影响的腿上捆绑压缩绷带时施加在腿上的压力。使用不当的压迫绷带可能是无效的,或者可能导致皮肤刺激、变色、皮肤凹陷等问题,也可能导致坏死。本文旨在提供一种力敏电阻(FSR)和发光二极管(led)与压缩绷带集成的压力指示系统,用于压力优化和静脉曲张的管理。通过在四周内测量受试者的静脉长度来验证压力指示系统的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Pressure optimization system for Varicose Veins management
Veins have one way valves inside them that open and close to keep the blood flowing towards the heart. Varicose veins represent a condition where the weak or damaged valves in the veins can cause blood to pool and even flow backwards. It is most common in pregnant women and the elderly. Compression therapy is an established treatment for varicose veins, where the applied pressure has to be in specific ranges in order to have an effective treatment. No method currently exists for monitoring the pressure applied in the leg while tying the compression bandage on the affected leg. Improper application of compression bandage can be ineffective or can cause issues such as skin irritation, discoloration, dent in skin and can also cause necrosis. This paper aims to provide a pressure indicating system with Force sensing resistor (FSR) and Light emitting diodes (LEDs) integrated with compression bandage for pressure optimization and management of varicose veins. The effectiveness of the pressure indicating system is validated by measuring the subject's vein length within a span of four weeks.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信