基于电压扫描和P & O的t源逆变器PV混合最大功率点跟踪算法

Alyaa Abdo Hassan, E. E. EL-Kholy, Hossam Youssef Abdel, H. Awad
{"title":"基于电压扫描和P & O的t源逆变器PV混合最大功率点跟踪算法","authors":"Alyaa Abdo Hassan, E. E. EL-Kholy, Hossam Youssef Abdel, H. Awad","doi":"10.1109/CPERE56564.2023.10119531","DOIUrl":null,"url":null,"abstract":"In this article, the analysis and implementation of a hybrid algorithm for maximum Point of Power tracking in photovoltaic applications is presented. The proposed algorithm merges the Voltage Sweep technique and the Perturb & Observe (P& O) algorithm to control a T-source inverter (TSI). The quadrature-axis component, on the other hand, is set to zero to improve the system’s power factor. After calculating the reference components, they are compared to actual values, and two PI controllers handle them. Then, the Simple Boost Control technique is employed to modulate the TSI. Various operational scenarios, such as irradiance and temperature variations, were simulated (using MATLAB) and investigated to validate the efficacy of the proposed algorithm. A quantitative comparison between the three methods is included.","PeriodicalId":169048,"journal":{"name":"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Hybrid Maximum-Power-Point Tracking Algorithm using Voltage Sweep and P & O for T-Source Inverter PV Applications\",\"authors\":\"Alyaa Abdo Hassan, E. E. EL-Kholy, Hossam Youssef Abdel, H. Awad\",\"doi\":\"10.1109/CPERE56564.2023.10119531\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this article, the analysis and implementation of a hybrid algorithm for maximum Point of Power tracking in photovoltaic applications is presented. The proposed algorithm merges the Voltage Sweep technique and the Perturb & Observe (P& O) algorithm to control a T-source inverter (TSI). The quadrature-axis component, on the other hand, is set to zero to improve the system’s power factor. After calculating the reference components, they are compared to actual values, and two PI controllers handle them. Then, the Simple Boost Control technique is employed to modulate the TSI. Various operational scenarios, such as irradiance and temperature variations, were simulated (using MATLAB) and investigated to validate the efficacy of the proposed algorithm. A quantitative comparison between the three methods is included.\",\"PeriodicalId\":169048,\"journal\":{\"name\":\"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)\",\"volume\":\"62 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-02-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CPERE56564.2023.10119531\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 IEEE Conference on Power Electronics and Renewable Energy (CPERE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPERE56564.2023.10119531","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文分析并实现了一种光伏应用中最大功率跟踪的混合算法。该算法融合了电压扫描技术和扰动与观察(P& O)算法来控制t源逆变器(TSI)。另一方面,正交轴组件被设置为零,以提高系统的功率因数。计算出参考分量后,将其与实际值进行比较,由两个PI控制器进行处理。然后,采用简单升压控制技术对TSI进行调制。利用MATLAB对辐照度和温度变化等各种操作场景进行了模拟和研究,以验证所提出算法的有效性。对这三种方法进行了定量比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Hybrid Maximum-Power-Point Tracking Algorithm using Voltage Sweep and P & O for T-Source Inverter PV Applications
In this article, the analysis and implementation of a hybrid algorithm for maximum Point of Power tracking in photovoltaic applications is presented. The proposed algorithm merges the Voltage Sweep technique and the Perturb & Observe (P& O) algorithm to control a T-source inverter (TSI). The quadrature-axis component, on the other hand, is set to zero to improve the system’s power factor. After calculating the reference components, they are compared to actual values, and two PI controllers handle them. Then, the Simple Boost Control technique is employed to modulate the TSI. Various operational scenarios, such as irradiance and temperature variations, were simulated (using MATLAB) and investigated to validate the efficacy of the proposed algorithm. A quantitative comparison between the three methods is included.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信