配电网保护的一种继电协调

Gaurav Kapoor
{"title":"配电网保护的一种继电协调","authors":"Gaurav Kapoor","doi":"10.58260/j.iet.2202.0103","DOIUrl":null,"url":null,"abstract":"Fault identification is a significant task on a distribution line (DL) when a harsh disturbance occurs due to breakdown of insulation on a DL. The termination of fault diagnosis on DL should be done as soon as probable to avoid further economic and communal costs due to interruptions of load. This paper proposes the application of wavelet and Fourier analysis for mapping the connection between 3-Φ current signals at one terminal and fault information on the DL. The proposed relaying system allows automatic adaption of the feature extraction accountable for fault identification. Simulation results performed by MATLAB, verify the high precision of the proposed relaying system in shaping the fault identification. In these simulations, it is exposed that the relaying system is independent of the parameters of the DL and accordingly, it is better to the active schemes.","PeriodicalId":156368,"journal":{"name":"Global Journal of Innovation and Emerging Technology","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A RELAYING COORDINATION FOR DISTRIBUTION NETWORK PROTECTION\",\"authors\":\"Gaurav Kapoor\",\"doi\":\"10.58260/j.iet.2202.0103\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Fault identification is a significant task on a distribution line (DL) when a harsh disturbance occurs due to breakdown of insulation on a DL. The termination of fault diagnosis on DL should be done as soon as probable to avoid further economic and communal costs due to interruptions of load. This paper proposes the application of wavelet and Fourier analysis for mapping the connection between 3-Φ current signals at one terminal and fault information on the DL. The proposed relaying system allows automatic adaption of the feature extraction accountable for fault identification. Simulation results performed by MATLAB, verify the high precision of the proposed relaying system in shaping the fault identification. In these simulations, it is exposed that the relaying system is independent of the parameters of the DL and accordingly, it is better to the active schemes.\",\"PeriodicalId\":156368,\"journal\":{\"name\":\"Global Journal of Innovation and Emerging Technology\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Global Journal of Innovation and Emerging Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.58260/j.iet.2202.0103\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global Journal of Innovation and Emerging Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.58260/j.iet.2202.0103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

当配电线路绝缘击穿引起严重干扰时,故障识别是配电线路的一项重要任务。为了避免因负荷中断而造成的进一步的经济和公共成本,应尽快终止DL故障诊断。本文提出了应用小波变换和傅立叶变换来映射一端3个-Φ电流信号与DL上故障信息之间的关系。所提出的继电系统允许自适应的特征提取负责故障识别。仿真结果验证了所提继电系统在整形故障识别方面的高精度。仿真结果表明,继电保护系统与DL参数无关,因此,继电保护方案优于有源方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A RELAYING COORDINATION FOR DISTRIBUTION NETWORK PROTECTION
Fault identification is a significant task on a distribution line (DL) when a harsh disturbance occurs due to breakdown of insulation on a DL. The termination of fault diagnosis on DL should be done as soon as probable to avoid further economic and communal costs due to interruptions of load. This paper proposes the application of wavelet and Fourier analysis for mapping the connection between 3-Φ current signals at one terminal and fault information on the DL. The proposed relaying system allows automatic adaption of the feature extraction accountable for fault identification. Simulation results performed by MATLAB, verify the high precision of the proposed relaying system in shaping the fault identification. In these simulations, it is exposed that the relaying system is independent of the parameters of the DL and accordingly, it is better to the active schemes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信