热循环前后排气孔对水泥上层建筑固力的影响

Jianrong Chen, K. Nagao, Y. Tomotake, K. Oka, M. Hada, T. Ichikawa
{"title":"热循环前后排气孔对水泥上层建筑固力的影响","authors":"Jianrong Chen, K. Nagao, Y. Tomotake, K. Oka, M. Hada, T. Ichikawa","doi":"10.2186/PRP.5.157","DOIUrl":null,"url":null,"abstract":"Purpose: The purpose of this study was to evaluate the influence of a vent hole on the retentive force of a cement-retained superstructure to an abutment.Methods: The retentive force of superstructures with/without a vent hole, retained using one of two luting cements, was measured using a universal testing machine both before and after thermocyclingResults: The retentive force of the cement-retained superstructure with the vent hole was greater than that of the cement-retained superstructure without the vent hole. While the retentive force decreased significantly after thermocycling, the size of the vent hole had little influence on the retentive force.Conclusion: It was concluded that placement of a vent hole in the superstructure is useful, with little adverse effect on the retentive force of the restoration.","PeriodicalId":306414,"journal":{"name":"Prosthodontic Research & Practice","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Influence of a Vent Hole on the Retentive Force of a Cement-retained Superstructure before/after Thermocycling\",\"authors\":\"Jianrong Chen, K. Nagao, Y. Tomotake, K. Oka, M. Hada, T. Ichikawa\",\"doi\":\"10.2186/PRP.5.157\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose: The purpose of this study was to evaluate the influence of a vent hole on the retentive force of a cement-retained superstructure to an abutment.Methods: The retentive force of superstructures with/without a vent hole, retained using one of two luting cements, was measured using a universal testing machine both before and after thermocyclingResults: The retentive force of the cement-retained superstructure with the vent hole was greater than that of the cement-retained superstructure without the vent hole. While the retentive force decreased significantly after thermocycling, the size of the vent hole had little influence on the retentive force.Conclusion: It was concluded that placement of a vent hole in the superstructure is useful, with little adverse effect on the retentive force of the restoration.\",\"PeriodicalId\":306414,\"journal\":{\"name\":\"Prosthodontic Research & Practice\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2006-11-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Prosthodontic Research & Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2186/PRP.5.157\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Prosthodontic Research & Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2186/PRP.5.157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目的:本研究的目的是评估通风口对水泥保留的上部结构对基台的固位力的影响。方法:在热循环前后,用万能试验机测量两种不同类型水泥中有/没有通风口的上部结构的固位力。结果:有通风口的上部结构的固位力大于没有通风口的上部结构。热循环后的固相力明显降低,排气孔尺寸对固相力影响不大。结论:在上部结构上放置一个排气孔是有用的,对修复体的固位力影响不大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of a Vent Hole on the Retentive Force of a Cement-retained Superstructure before/after Thermocycling
Purpose: The purpose of this study was to evaluate the influence of a vent hole on the retentive force of a cement-retained superstructure to an abutment.Methods: The retentive force of superstructures with/without a vent hole, retained using one of two luting cements, was measured using a universal testing machine both before and after thermocyclingResults: The retentive force of the cement-retained superstructure with the vent hole was greater than that of the cement-retained superstructure without the vent hole. While the retentive force decreased significantly after thermocycling, the size of the vent hole had little influence on the retentive force.Conclusion: It was concluded that placement of a vent hole in the superstructure is useful, with little adverse effect on the retentive force of the restoration.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信