不同角膜测量数据及计算方法对环形人工晶状体植入术矫正角膜散光的比较评价

E. Boiko, S. Shukhaev, S. S. Kudlakhmedov, I. Litvin
{"title":"不同角膜测量数据及计算方法对环形人工晶状体植入术矫正角膜散光的比较评价","authors":"E. Boiko, S. Shukhaev, S. S. Kudlakhmedov, I. Litvin","doi":"10.25276/0235-4160-2022-4-36-44","DOIUrl":null,"url":null,"abstract":"Purpose. Compare the effectiveness of regular corneal astigmatism correction with toric monofocal IOL using various keratometric data and calculation methods. Material and methods. The study included 28 patients (31 eyes) with age-related cataracts and regular corneal astigmatism who underwent phacoemulsification (n=31) with implantation of a monofocal toric IOL (EnVista Toric). Two groups were formed according to the type of calculation and possible options of keratometric data: 1) keratometric data of IOL-master 500 + online manufacturer's calculator; 2) keratometric data of the anterior and posterior corneal surfaces (Pentacam HR) + Barrett's toric calculator. Results. The mean absolute deviation of the predicted residual astigmatism from the actual one was distributed as follows: 1st group – 0.62±0.62 D, 2nd group – 0.41 ± 0.71 D. The values of the mean absolute vector and mean centroid error in diopters were: 0.80±0.59 D and 0.06 D in 1st group, 0.48±0.65 D and 0.02 D in 2nd group, respectively. Conclusion. When using the measured astigmatism of the anterior and posterior surface of the cornea, Barrett's toric calculator showed the best result. The most accurate forecast of residual astigmatism was obtained using the Barrett calculator in combination with Pentacam keratometry data (Axial\\Sagittal (Front), Axial\\Sagittal (Back)). Key words: corneal astigmatism, posterior corneal astigmatism, toric IOL, centroid analysis, keratometry, cataract surgery","PeriodicalId":424200,"journal":{"name":"Fyodorov journal of ophthalmic surgery","volume":"74 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Comparative evaluation of surgical correction of corneal astigmatism by toric IOL implantation using various keratometric data and calculation methods\",\"authors\":\"E. Boiko, S. Shukhaev, S. S. Kudlakhmedov, I. Litvin\",\"doi\":\"10.25276/0235-4160-2022-4-36-44\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Purpose. Compare the effectiveness of regular corneal astigmatism correction with toric monofocal IOL using various keratometric data and calculation methods. Material and methods. The study included 28 patients (31 eyes) with age-related cataracts and regular corneal astigmatism who underwent phacoemulsification (n=31) with implantation of a monofocal toric IOL (EnVista Toric). Two groups were formed according to the type of calculation and possible options of keratometric data: 1) keratometric data of IOL-master 500 + online manufacturer's calculator; 2) keratometric data of the anterior and posterior corneal surfaces (Pentacam HR) + Barrett's toric calculator. Results. The mean absolute deviation of the predicted residual astigmatism from the actual one was distributed as follows: 1st group – 0.62±0.62 D, 2nd group – 0.41 ± 0.71 D. The values of the mean absolute vector and mean centroid error in diopters were: 0.80±0.59 D and 0.06 D in 1st group, 0.48±0.65 D and 0.02 D in 2nd group, respectively. Conclusion. When using the measured astigmatism of the anterior and posterior surface of the cornea, Barrett's toric calculator showed the best result. The most accurate forecast of residual astigmatism was obtained using the Barrett calculator in combination with Pentacam keratometry data (Axial\\\\Sagittal (Front), Axial\\\\Sagittal (Back)). Key words: corneal astigmatism, posterior corneal astigmatism, toric IOL, centroid analysis, keratometry, cataract surgery\",\"PeriodicalId\":424200,\"journal\":{\"name\":\"Fyodorov journal of ophthalmic surgery\",\"volume\":\"74 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fyodorov journal of ophthalmic surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.25276/0235-4160-2022-4-36-44\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fyodorov journal of ophthalmic surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25276/0235-4160-2022-4-36-44","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

目的。采用不同的角膜度数和计算方法,比较常规散光和环形单焦点人工晶状体的矫正效果。材料和方法。该研究纳入了28例(31只眼)年龄相关性白内障和常规角膜散光患者,他们接受了超声乳化术(n=31)并植入单焦点环形人工晶状体(EnVista toric)。根据角膜测量数据的计算类型和可能选择分为两组:1)IOL-master 500 +在线制造商计算器的角膜测量数据;2)角膜前、后表面角膜测量数据(Pentacam HR) + Barrett’s toric计算器。结果。预测残差与实际残差的平均绝对偏差分布为:第一组- 0.62±0.62 D,第二组- 0.41±0.71 D。屈光度平均绝对矢量和平均质心误差分别为:第一组0.80±0.59 D和0.06 D,第二组0.48±0.65 D和0.02 D。结论。使用Barrett的屈光度计算器测量角膜前、后表面的散光,结果最好。使用Barrett计算器结合Pentacam角膜测量数据(轴向\矢状(前),轴向\矢状(后))获得最准确的剩余散光预测。关键词:角膜散光,后角膜散光,环形人工晶状体,质心分析,角膜测光,白内障手术
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative evaluation of surgical correction of corneal astigmatism by toric IOL implantation using various keratometric data and calculation methods
Purpose. Compare the effectiveness of regular corneal astigmatism correction with toric monofocal IOL using various keratometric data and calculation methods. Material and methods. The study included 28 patients (31 eyes) with age-related cataracts and regular corneal astigmatism who underwent phacoemulsification (n=31) with implantation of a monofocal toric IOL (EnVista Toric). Two groups were formed according to the type of calculation and possible options of keratometric data: 1) keratometric data of IOL-master 500 + online manufacturer's calculator; 2) keratometric data of the anterior and posterior corneal surfaces (Pentacam HR) + Barrett's toric calculator. Results. The mean absolute deviation of the predicted residual astigmatism from the actual one was distributed as follows: 1st group – 0.62±0.62 D, 2nd group – 0.41 ± 0.71 D. The values of the mean absolute vector and mean centroid error in diopters were: 0.80±0.59 D and 0.06 D in 1st group, 0.48±0.65 D and 0.02 D in 2nd group, respectively. Conclusion. When using the measured astigmatism of the anterior and posterior surface of the cornea, Barrett's toric calculator showed the best result. The most accurate forecast of residual astigmatism was obtained using the Barrett calculator in combination with Pentacam keratometry data (Axial\Sagittal (Front), Axial\Sagittal (Back)). Key words: corneal astigmatism, posterior corneal astigmatism, toric IOL, centroid analysis, keratometry, cataract surgery
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信