{"title":"模拟商业和公用事业规模的光伏阵列由于短串的失配损失","authors":"Ryan M. Smith, Manjunath Matam, H. Seigneur","doi":"10.1109/pvsc48317.2022.9938878","DOIUrl":null,"url":null,"abstract":"The intentional removal of one or more photovoltaic modules from a string, thus shortening the length of the string relative to others within the array, may occur for a variety of reasons. The result is a mismatch in string length which our previous work has shown to impact the operation of the array by 1) shifting the ideal maximum power point of the array, and 2) inducing reverse currents in the shortened strings at VOC, a condition experienced by arrays under normal operation and during some maintenance activities. This work takes the experimentally verified simulation results of our previous small-scale studies and expands the simulations to elucidate behaviors at commercial and utility scales.","PeriodicalId":435386,"journal":{"name":"2022 IEEE 49th Photovoltaics Specialists Conference (PVSC)","volume":"182 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mismatch Losses in Simulated Commercial and Utility-scale PV Arrays due to Shortened Strings\",\"authors\":\"Ryan M. Smith, Manjunath Matam, H. Seigneur\",\"doi\":\"10.1109/pvsc48317.2022.9938878\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The intentional removal of one or more photovoltaic modules from a string, thus shortening the length of the string relative to others within the array, may occur for a variety of reasons. The result is a mismatch in string length which our previous work has shown to impact the operation of the array by 1) shifting the ideal maximum power point of the array, and 2) inducing reverse currents in the shortened strings at VOC, a condition experienced by arrays under normal operation and during some maintenance activities. This work takes the experimentally verified simulation results of our previous small-scale studies and expands the simulations to elucidate behaviors at commercial and utility scales.\",\"PeriodicalId\":435386,\"journal\":{\"name\":\"2022 IEEE 49th Photovoltaics Specialists Conference (PVSC)\",\"volume\":\"182 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE 49th Photovoltaics Specialists Conference (PVSC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/pvsc48317.2022.9938878\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 49th Photovoltaics Specialists Conference (PVSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/pvsc48317.2022.9938878","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于多种原因,可能会有意地从串上移除一个或多个光伏组件,从而缩短该串相对于阵列内其他组件的长度。结果是字符串长度不匹配,我们之前的工作表明,它会影响阵列的运行:1)移动阵列的理想最大功率点;2)在VOC下,在缩短的字符串中产生反向电流,这是阵列在正常运行和一些维护活动中遇到的情况。本研究采用了我们之前小规模研究的实验验证模拟结果,并扩展了模拟以阐明商业和公用事业规模的行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Mismatch Losses in Simulated Commercial and Utility-scale PV Arrays due to Shortened Strings
The intentional removal of one or more photovoltaic modules from a string, thus shortening the length of the string relative to others within the array, may occur for a variety of reasons. The result is a mismatch in string length which our previous work has shown to impact the operation of the array by 1) shifting the ideal maximum power point of the array, and 2) inducing reverse currents in the shortened strings at VOC, a condition experienced by arrays under normal operation and during some maintenance activities. This work takes the experimentally verified simulation results of our previous small-scale studies and expands the simulations to elucidate behaviors at commercial and utility scales.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信