高达10mhz的高压差分探头通带频率响应测量

Michael Grubmüiller, M. Neumayer
{"title":"高达10mhz的高压差分探头通带频率响应测量","authors":"Michael Grubmüiller, M. Neumayer","doi":"10.1109/I2MTC.2019.8827019","DOIUrl":null,"url":null,"abstract":"High voltage differential probes are widely used for measurements in power electronics. For accurate measurements in power electronics, the use of probes with flat passband frequency response is indispensable. In this article we present a measurement method to evaluate the passband frequency response of a probe up to 10 MHz. We introduce an oscilloscope based setup, including a calibration procedure with a reference attenuator. Amplitude and phase estimation of the oscilloscope data is done with enhanced versions of the IEEE 1057 and 1251 sine-wave fit algorithms. The feasibility of the presented method is verified by a detailed uncertainty evaluation for the complex valued passband frequency response. The uncertainty assessment is done with two different methods, provided by the Guide to the Expression of Uncertainty in Measurement (GUM) and the associated Supplement 2.","PeriodicalId":132588,"journal":{"name":"2019 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","volume":"71 11","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Passband frequency response measurement of a high voltage differential probe up to 10 MHz\",\"authors\":\"Michael Grubmüiller, M. Neumayer\",\"doi\":\"10.1109/I2MTC.2019.8827019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High voltage differential probes are widely used for measurements in power electronics. For accurate measurements in power electronics, the use of probes with flat passband frequency response is indispensable. In this article we present a measurement method to evaluate the passband frequency response of a probe up to 10 MHz. We introduce an oscilloscope based setup, including a calibration procedure with a reference attenuator. Amplitude and phase estimation of the oscilloscope data is done with enhanced versions of the IEEE 1057 and 1251 sine-wave fit algorithms. The feasibility of the presented method is verified by a detailed uncertainty evaluation for the complex valued passband frequency response. The uncertainty assessment is done with two different methods, provided by the Guide to the Expression of Uncertainty in Measurement (GUM) and the associated Supplement 2.\",\"PeriodicalId\":132588,\"journal\":{\"name\":\"2019 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)\",\"volume\":\"71 11\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/I2MTC.2019.8827019\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE International Instrumentation and Measurement Technology Conference (I2MTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/I2MTC.2019.8827019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

高压差动探头广泛用于电力电子测量。为了在电力电子中进行精确测量,使用具有平坦通带频率响应的探头是必不可少的。在本文中,我们提出了一种测量方法来评估高达10mhz的探头的通带频率响应。我们介绍了一个基于示波器的设置,包括一个带有参考衰减器的校准程序。示波器数据的幅度和相位估计是用IEEE 1057和1251正弦波拟合算法的增强版本完成的。通过对复值通带频率响应的不确定度评估,验证了该方法的可行性。不确定度评估采用两种不同的方法进行,由《测量不确定度表达指南》(GUM)和相关的附录2提供。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Passband frequency response measurement of a high voltage differential probe up to 10 MHz
High voltage differential probes are widely used for measurements in power electronics. For accurate measurements in power electronics, the use of probes with flat passband frequency response is indispensable. In this article we present a measurement method to evaluate the passband frequency response of a probe up to 10 MHz. We introduce an oscilloscope based setup, including a calibration procedure with a reference attenuator. Amplitude and phase estimation of the oscilloscope data is done with enhanced versions of the IEEE 1057 and 1251 sine-wave fit algorithms. The feasibility of the presented method is verified by a detailed uncertainty evaluation for the complex valued passband frequency response. The uncertainty assessment is done with two different methods, provided by the Guide to the Expression of Uncertainty in Measurement (GUM) and the associated Supplement 2.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信