{"title":"SF6断路器介电强度冷升速率的研究","authors":"D. Chernoskutov","doi":"10.1109/SIBCON.2015.7147274","DOIUrl":null,"url":null,"abstract":"This paper is connected with investigation of cold rate of rise of electric strength of 525 kV SF6 live tank circuit breaker. The article describes controlled opening during opening operation of puffer SF6 Circuit Breaker. The method gives the real estimation of gas flow influence to dynamic breakdown characteristic of puffer interrupter. The purpose of this article is to give the correlation between breakdown voltage characteristic and opening speed of circuit breaker as well from changing of filling pressure value.","PeriodicalId":395729,"journal":{"name":"2015 International Siberian Conference on Control and Communications (SIBCON)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Research of cold rate of rise of dielectric strength of SF6 circuit breaker\",\"authors\":\"D. Chernoskutov\",\"doi\":\"10.1109/SIBCON.2015.7147274\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper is connected with investigation of cold rate of rise of electric strength of 525 kV SF6 live tank circuit breaker. The article describes controlled opening during opening operation of puffer SF6 Circuit Breaker. The method gives the real estimation of gas flow influence to dynamic breakdown characteristic of puffer interrupter. The purpose of this article is to give the correlation between breakdown voltage characteristic and opening speed of circuit breaker as well from changing of filling pressure value.\",\"PeriodicalId\":395729,\"journal\":{\"name\":\"2015 International Siberian Conference on Control and Communications (SIBCON)\",\"volume\":\"38 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Siberian Conference on Control and Communications (SIBCON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIBCON.2015.7147274\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Siberian Conference on Control and Communications (SIBCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIBCON.2015.7147274","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Research of cold rate of rise of dielectric strength of SF6 circuit breaker
This paper is connected with investigation of cold rate of rise of electric strength of 525 kV SF6 live tank circuit breaker. The article describes controlled opening during opening operation of puffer SF6 Circuit Breaker. The method gives the real estimation of gas flow influence to dynamic breakdown characteristic of puffer interrupter. The purpose of this article is to give the correlation between breakdown voltage characteristic and opening speed of circuit breaker as well from changing of filling pressure value.