E. Gulski, S. Meijer, J. Smit, F. Wester, P. Seitz
{"title":"交流阻尼电压下传输电缆PD检测","authors":"E. Gulski, S. Meijer, J. Smit, F. Wester, P. Seitz","doi":"10.1109/ELINSL.2004.1380645","DOIUrl":null,"url":null,"abstract":"This contribution presents new method for on-site PD diagnosis on HV transmission power cables. To on-site energize and to ignite partial discharges in transmission power cables, damped AC voltages up to 250 kV are generated. As a result, sensitive partial discharges detection and PD site location is possible. The developed system as well as PD measurements are shown to demonstrate the principles of this on-site diagnosis on HV transmission cables.","PeriodicalId":342687,"journal":{"name":"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation","volume":"68 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Transmission power cables PD detection at damped AC voltages\",\"authors\":\"E. Gulski, S. Meijer, J. Smit, F. Wester, P. Seitz\",\"doi\":\"10.1109/ELINSL.2004.1380645\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This contribution presents new method for on-site PD diagnosis on HV transmission power cables. To on-site energize and to ignite partial discharges in transmission power cables, damped AC voltages up to 250 kV are generated. As a result, sensitive partial discharges detection and PD site location is possible. The developed system as well as PD measurements are shown to demonstrate the principles of this on-site diagnosis on HV transmission cables.\",\"PeriodicalId\":342687,\"journal\":{\"name\":\"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation\",\"volume\":\"68 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-09-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2004.1380645\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the 2004 IEEE International Symposium on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2004.1380645","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Transmission power cables PD detection at damped AC voltages
This contribution presents new method for on-site PD diagnosis on HV transmission power cables. To on-site energize and to ignite partial discharges in transmission power cables, damped AC voltages up to 250 kV are generated. As a result, sensitive partial discharges detection and PD site location is possible. The developed system as well as PD measurements are shown to demonstrate the principles of this on-site diagnosis on HV transmission cables.