S. Shahidi, İbrahim Özkaya, Çağatay Selçuk Karakaş, Yavuz Taşkıran, J. Esformes
{"title":"用Powrlink便携式仪器测量等长肌力的效度和信度","authors":"S. Shahidi, İbrahim Özkaya, Çağatay Selçuk Karakaş, Yavuz Taşkıran, J. Esformes","doi":"10.47206/ijsc.v3i1.237","DOIUrl":null,"url":null,"abstract":"Background: A muscle strength testing device that is convenient, practical, reliable, and valid is essential in clinical and field settings. Objective: Therefore, the purpose of this study was to determine the validity and reliability of measuring isometric muscle strength with the Powrlink handheld dynamometer compared to an established force dynamometer. Method: Sixty-one university students (40 males and 21 females) completed two standardized testing sessions seven days apart. Each session consisted of a familiarization period followed by three peak isometric muscle strength tests. Intraclass correlation (ICC, model: two-way mixture with absolute agreement), standard error of measurement (SEM), minimum detectable change (MDC), and 95% limits of agreement (LOA) for intra- and inter-rater reliability were determined. Results: Test-retest reliability (ICC > 0.91) and intertrial reliability (ICC > 0.99) were excellent. No significant differences were observed in peak and mean knee forces and torques between the test and retest, indicating high test-retest reliability. Conclusion: The Powrlink device is portable, convenient, responsive, and cost-effective, has excellent test-retest reliability, and can be used to measure maximal isometric force in the clinic and in the field.","PeriodicalId":170948,"journal":{"name":"International Journal of Strength and Conditioning","volume":"119 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validity and Reliability of Isometric Muscle Strength using the Powrlink Portable Device\",\"authors\":\"S. Shahidi, İbrahim Özkaya, Çağatay Selçuk Karakaş, Yavuz Taşkıran, J. Esformes\",\"doi\":\"10.47206/ijsc.v3i1.237\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: A muscle strength testing device that is convenient, practical, reliable, and valid is essential in clinical and field settings. Objective: Therefore, the purpose of this study was to determine the validity and reliability of measuring isometric muscle strength with the Powrlink handheld dynamometer compared to an established force dynamometer. Method: Sixty-one university students (40 males and 21 females) completed two standardized testing sessions seven days apart. Each session consisted of a familiarization period followed by three peak isometric muscle strength tests. Intraclass correlation (ICC, model: two-way mixture with absolute agreement), standard error of measurement (SEM), minimum detectable change (MDC), and 95% limits of agreement (LOA) for intra- and inter-rater reliability were determined. Results: Test-retest reliability (ICC > 0.91) and intertrial reliability (ICC > 0.99) were excellent. No significant differences were observed in peak and mean knee forces and torques between the test and retest, indicating high test-retest reliability. Conclusion: The Powrlink device is portable, convenient, responsive, and cost-effective, has excellent test-retest reliability, and can be used to measure maximal isometric force in the clinic and in the field.\",\"PeriodicalId\":170948,\"journal\":{\"name\":\"International Journal of Strength and Conditioning\",\"volume\":\"119 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Strength and Conditioning\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.47206/ijsc.v3i1.237\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Strength and Conditioning","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47206/ijsc.v3i1.237","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Validity and Reliability of Isometric Muscle Strength using the Powrlink Portable Device
Background: A muscle strength testing device that is convenient, practical, reliable, and valid is essential in clinical and field settings. Objective: Therefore, the purpose of this study was to determine the validity and reliability of measuring isometric muscle strength with the Powrlink handheld dynamometer compared to an established force dynamometer. Method: Sixty-one university students (40 males and 21 females) completed two standardized testing sessions seven days apart. Each session consisted of a familiarization period followed by three peak isometric muscle strength tests. Intraclass correlation (ICC, model: two-way mixture with absolute agreement), standard error of measurement (SEM), minimum detectable change (MDC), and 95% limits of agreement (LOA) for intra- and inter-rater reliability were determined. Results: Test-retest reliability (ICC > 0.91) and intertrial reliability (ICC > 0.99) were excellent. No significant differences were observed in peak and mean knee forces and torques between the test and retest, indicating high test-retest reliability. Conclusion: The Powrlink device is portable, convenient, responsive, and cost-effective, has excellent test-retest reliability, and can be used to measure maximal isometric force in the clinic and in the field.