基于UPFC的环路配电系统线损最小控制

M. A. Sayed, N. Inayoshi, T. Takeshits, F. Ueda
{"title":"基于UPFC的环路配电系统线损最小控制","authors":"M. A. Sayed, N. Inayoshi, T. Takeshits, F. Ueda","doi":"10.1109/PCCON.2007.373087","DOIUrl":null,"url":null,"abstract":"This paper presents an elaborated mathematical analysis of the line loss minimum condition of loop distribution systems. In order to achieve this condition, the unified power flow controller (UPFC), a typical FACTS (flexible AC transmission systems) device that is capable of instantaneous control of transmission and distribution power flow, is used. Also, the available control schemes of the UPFC to minimize the total line loss of the loop distribution system are presented. The authors propose the line inductance compensation control and the line voltage compensation control which can be applied to the loop distribution system according to the line parameters. The effectiveness of the proposed control scheme, line inductance compensation control, has been verified experimentally using laboratory prototype in a 200 V, 6 kVA system.","PeriodicalId":325362,"journal":{"name":"2007 Power Conversion Conference - Nagoya","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Line Loss Minimum Control of Loop Distribution Systems Using UPFC\",\"authors\":\"M. A. Sayed, N. Inayoshi, T. Takeshits, F. Ueda\",\"doi\":\"10.1109/PCCON.2007.373087\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents an elaborated mathematical analysis of the line loss minimum condition of loop distribution systems. In order to achieve this condition, the unified power flow controller (UPFC), a typical FACTS (flexible AC transmission systems) device that is capable of instantaneous control of transmission and distribution power flow, is used. Also, the available control schemes of the UPFC to minimize the total line loss of the loop distribution system are presented. The authors propose the line inductance compensation control and the line voltage compensation control which can be applied to the loop distribution system according to the line parameters. The effectiveness of the proposed control scheme, line inductance compensation control, has been verified experimentally using laboratory prototype in a 200 V, 6 kVA system.\",\"PeriodicalId\":325362,\"journal\":{\"name\":\"2007 Power Conversion Conference - Nagoya\",\"volume\":\"76 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-04-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 Power Conversion Conference - Nagoya\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PCCON.2007.373087\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 Power Conversion Conference - Nagoya","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCCON.2007.373087","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

本文对环形配电系统的线损最小条件进行了详细的数学分析。为了实现这一条件,统一潮流控制器(UPFC)是一种典型的能够瞬时控制输配电潮流的柔性交流输电系统(FACTS)设备。同时,提出了UPFC的控制方案,使环路配电系统的总线路损耗最小。根据线路参数,提出了适用于环路配电系统的线路电感补偿控制和线路电压补偿控制。所提出的线路电感补偿控制方案的有效性已在200v, 6kva系统的实验室样机上得到了实验验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Line Loss Minimum Control of Loop Distribution Systems Using UPFC
This paper presents an elaborated mathematical analysis of the line loss minimum condition of loop distribution systems. In order to achieve this condition, the unified power flow controller (UPFC), a typical FACTS (flexible AC transmission systems) device that is capable of instantaneous control of transmission and distribution power flow, is used. Also, the available control schemes of the UPFC to minimize the total line loss of the loop distribution system are presented. The authors propose the line inductance compensation control and the line voltage compensation control which can be applied to the loop distribution system according to the line parameters. The effectiveness of the proposed control scheme, line inductance compensation control, has been verified experimentally using laboratory prototype in a 200 V, 6 kVA system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信