{"title":"斯科特变压器耦合并网光伏逆变器的容错拓扑","authors":"Mai Tuan Dat, T. Wijnhoven, J. Driesen","doi":"10.1109/ASSCC.2012.6523306","DOIUrl":null,"url":null,"abstract":"A grid-connected photovoltaic(PV) power plant is mainly based on power electronics equipments which are considered as the most vulnerable parts in a PV system. In order to increase the reliability of modular grid-connected PV panel, a solution by using a Scott transformer is presented to reduce the number of switches and to continuously operate the PV system in case of switch-failures of the power converter. The three-phase type PV inverter is analyzed in the normal and fault-operation. The simulation has shown that fault tolerance can be achieved with the proposed system configuration to give a redundancy of power switches in an Integrated power electronic module. Index Terms-Power converter, Scott transformer, redundant components, fault-tolerant, grid-connected inverter, grid-tie, reference frame, Clarke transformation.","PeriodicalId":341348,"journal":{"name":"2012 10th International Power & Energy Conference (IPEC)","volume":"204 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Fault-tolerant topology of a grid-connected PV inverter coupled by a Scott transformer\",\"authors\":\"Mai Tuan Dat, T. Wijnhoven, J. Driesen\",\"doi\":\"10.1109/ASSCC.2012.6523306\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A grid-connected photovoltaic(PV) power plant is mainly based on power electronics equipments which are considered as the most vulnerable parts in a PV system. In order to increase the reliability of modular grid-connected PV panel, a solution by using a Scott transformer is presented to reduce the number of switches and to continuously operate the PV system in case of switch-failures of the power converter. The three-phase type PV inverter is analyzed in the normal and fault-operation. The simulation has shown that fault tolerance can be achieved with the proposed system configuration to give a redundancy of power switches in an Integrated power electronic module. Index Terms-Power converter, Scott transformer, redundant components, fault-tolerant, grid-connected inverter, grid-tie, reference frame, Clarke transformation.\",\"PeriodicalId\":341348,\"journal\":{\"name\":\"2012 10th International Power & Energy Conference (IPEC)\",\"volume\":\"204 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 10th International Power & Energy Conference (IPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ASSCC.2012.6523306\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 10th International Power & Energy Conference (IPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASSCC.2012.6523306","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Fault-tolerant topology of a grid-connected PV inverter coupled by a Scott transformer
A grid-connected photovoltaic(PV) power plant is mainly based on power electronics equipments which are considered as the most vulnerable parts in a PV system. In order to increase the reliability of modular grid-connected PV panel, a solution by using a Scott transformer is presented to reduce the number of switches and to continuously operate the PV system in case of switch-failures of the power converter. The three-phase type PV inverter is analyzed in the normal and fault-operation. The simulation has shown that fault tolerance can be achieved with the proposed system configuration to give a redundancy of power switches in an Integrated power electronic module. Index Terms-Power converter, Scott transformer, redundant components, fault-tolerant, grid-connected inverter, grid-tie, reference frame, Clarke transformation.