N. Martiny, Jan Geder, Yuxi Wang, Werner Kraus, A. Jossen
{"title":"用于锂离子袋状电池原位温度测量的薄膜热电偶矩阵的研制","authors":"N. Martiny, Jan Geder, Yuxi Wang, Werner Kraus, A. Jossen","doi":"10.1109/ICSENS.2013.6688485","DOIUrl":null,"url":null,"abstract":"As cooling systems in battery systems lead to a falsified temperature measurement when surface based temperature monitoring techniques are applied, the development of a sensor for in-situ temperature monitoring is crucial. The authors present therefore different restrictions that need to be considered when designing such a sensor. First prototypes are developed as a proof of concept of using a common potential for a thermocouple matrix that will later provide a space resolved temperature monitoring in a cell. The influence of the sensor on the cell and vice versa is investigated and improvements for further design steps are elaborated.","PeriodicalId":258260,"journal":{"name":"2013 IEEE SENSORS","volume":"12 5","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Development of a thin-film thermocouple matrix for in-situ temperature measurement in a lithium ion pouch cell\",\"authors\":\"N. Martiny, Jan Geder, Yuxi Wang, Werner Kraus, A. Jossen\",\"doi\":\"10.1109/ICSENS.2013.6688485\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As cooling systems in battery systems lead to a falsified temperature measurement when surface based temperature monitoring techniques are applied, the development of a sensor for in-situ temperature monitoring is crucial. The authors present therefore different restrictions that need to be considered when designing such a sensor. First prototypes are developed as a proof of concept of using a common potential for a thermocouple matrix that will later provide a space resolved temperature monitoring in a cell. The influence of the sensor on the cell and vice versa is investigated and improvements for further design steps are elaborated.\",\"PeriodicalId\":258260,\"journal\":{\"name\":\"2013 IEEE SENSORS\",\"volume\":\"12 5\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE SENSORS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2013.6688485\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE SENSORS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2013.6688485","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of a thin-film thermocouple matrix for in-situ temperature measurement in a lithium ion pouch cell
As cooling systems in battery systems lead to a falsified temperature measurement when surface based temperature monitoring techniques are applied, the development of a sensor for in-situ temperature monitoring is crucial. The authors present therefore different restrictions that need to be considered when designing such a sensor. First prototypes are developed as a proof of concept of using a common potential for a thermocouple matrix that will later provide a space resolved temperature monitoring in a cell. The influence of the sensor on the cell and vice versa is investigated and improvements for further design steps are elaborated.