Hee-Woon Kim, Jin-Gyu Youn, J. Hur, Byeong-Woo Kim
{"title":"考虑极槽组合的IPM型无刷直流电机定子转矩故障特性分析","authors":"Hee-Woon Kim, Jin-Gyu Youn, J. Hur, Byeong-Woo Kim","doi":"10.1109/CEFC.2010.5481677","DOIUrl":null,"url":null,"abstract":"This paper presents that torque characteristic according to the pole/slot combination is analyzed under a stator-turn fault. The circulating current affects increasing input current and aggravating torque characteristic under a stator-fault. This paper is made of the modeling of 8-pole 12-slot and 10-pole 12-slot motors using the developed FEM-base model and analyzed the torque characteristic according to the circulating current and input current under a stator-turn fault.","PeriodicalId":148739,"journal":{"name":"Digests of the 2010 14th Biennial IEEE Conference on Electromagnetic Field Computation","volume":" 8","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Torque characteristic analysis of IPM type BLDC motor considering pole/slot combination under stator-turn fault condition\",\"authors\":\"Hee-Woon Kim, Jin-Gyu Youn, J. Hur, Byeong-Woo Kim\",\"doi\":\"10.1109/CEFC.2010.5481677\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents that torque characteristic according to the pole/slot combination is analyzed under a stator-turn fault. The circulating current affects increasing input current and aggravating torque characteristic under a stator-fault. This paper is made of the modeling of 8-pole 12-slot and 10-pole 12-slot motors using the developed FEM-base model and analyzed the torque characteristic according to the circulating current and input current under a stator-turn fault.\",\"PeriodicalId\":148739,\"journal\":{\"name\":\"Digests of the 2010 14th Biennial IEEE Conference on Electromagnetic Field Computation\",\"volume\":\" 8\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-05-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digests of the 2010 14th Biennial IEEE Conference on Electromagnetic Field Computation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEFC.2010.5481677\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digests of the 2010 14th Biennial IEEE Conference on Electromagnetic Field Computation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEFC.2010.5481677","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Torque characteristic analysis of IPM type BLDC motor considering pole/slot combination under stator-turn fault condition
This paper presents that torque characteristic according to the pole/slot combination is analyzed under a stator-turn fault. The circulating current affects increasing input current and aggravating torque characteristic under a stator-fault. This paper is made of the modeling of 8-pole 12-slot and 10-pole 12-slot motors using the developed FEM-base model and analyzed the torque characteristic according to the circulating current and input current under a stator-turn fault.