在没有任何外部持续激励信号的情况下,直接闭环识别奈奎斯特频率以上的机械共振

Weili Yan, C. Du, C. Pang
{"title":"在没有任何外部持续激励信号的情况下,直接闭环识别奈奎斯特频率以上的机械共振","authors":"Weili Yan, C. Du, C. Pang","doi":"10.1109/IECON.2014.7048896","DOIUrl":null,"url":null,"abstract":"In this paper, a general multirate approach is proposed for direct closed-loop identification of mechanical resonances above the Nyquist frequency without injecting any external persistently exciting (PE) signals. Based on the polynomial transformation technique, an extended least-squares (ELS) algorithm is designed to estimate parameters of the mixed-rate model, from which parameters of the fast-rate model is extracted. Convergence properties of the ELS algorithm are analyzed, and the parameter identifiability is ensured if the plant output sampling rate is non-integer multiples of the controller sampling rate. The performance of the proposed approach is evaluated by simulation results on the head-positioning servo control system of a hard disk drive (HDD) during track-following mode, where no external PE signal is added on.","PeriodicalId":228897,"journal":{"name":"IECON 2014 - 40th Annual Conference of the IEEE Industrial Electronics Society","volume":"27 9","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Direct closed-loop identification of mechanical resonances above the nyquist frequency without any external persistently exciting signals\",\"authors\":\"Weili Yan, C. Du, C. Pang\",\"doi\":\"10.1109/IECON.2014.7048896\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a general multirate approach is proposed for direct closed-loop identification of mechanical resonances above the Nyquist frequency without injecting any external persistently exciting (PE) signals. Based on the polynomial transformation technique, an extended least-squares (ELS) algorithm is designed to estimate parameters of the mixed-rate model, from which parameters of the fast-rate model is extracted. Convergence properties of the ELS algorithm are analyzed, and the parameter identifiability is ensured if the plant output sampling rate is non-integer multiples of the controller sampling rate. The performance of the proposed approach is evaluated by simulation results on the head-positioning servo control system of a hard disk drive (HDD) during track-following mode, where no external PE signal is added on.\",\"PeriodicalId\":228897,\"journal\":{\"name\":\"IECON 2014 - 40th Annual Conference of the IEEE Industrial Electronics Society\",\"volume\":\"27 9\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IECON 2014 - 40th Annual Conference of the IEEE Industrial Electronics Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IECON.2014.7048896\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2014 - 40th Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.2014.7048896","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文提出了在不注入任何外部持续激励(PE)信号的情况下,直接闭环识别奈奎斯特频率以上机械共振的通用多速率方法。基于多项式变换技术,设计了一种扩展最小二乘(ELS)算法来估计混合速率模型的参数,并从中提取出快速速率模型的参数。分析了ELS算法的收敛性,当被控对象输出采样率为控制器采样率的非整数倍时,保证了ELS算法参数的可辨识性。通过对硬盘驱动器(HDD)的头部定位伺服控制系统在轨迹跟踪模式下,在没有外部PE信号的情况下的仿真结果来评价该方法的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Direct closed-loop identification of mechanical resonances above the nyquist frequency without any external persistently exciting signals
In this paper, a general multirate approach is proposed for direct closed-loop identification of mechanical resonances above the Nyquist frequency without injecting any external persistently exciting (PE) signals. Based on the polynomial transformation technique, an extended least-squares (ELS) algorithm is designed to estimate parameters of the mixed-rate model, from which parameters of the fast-rate model is extracted. Convergence properties of the ELS algorithm are analyzed, and the parameter identifiability is ensured if the plant output sampling rate is non-integer multiples of the controller sampling rate. The performance of the proposed approach is evaluated by simulation results on the head-positioning servo control system of a hard disk drive (HDD) during track-following mode, where no external PE signal is added on.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信