三柱绝缘子线性缺陷对电场畸变影响的研究

Zehua Wu, Haoran Wang, H. Tian, B. Cui, Shiyi Zhou, Zongren Peng
{"title":"三柱绝缘子线性缺陷对电场畸变影响的研究","authors":"Zehua Wu, Haoran Wang, H. Tian, B. Cui, Shiyi Zhou, Zongren Peng","doi":"10.1109/CEIDP.2018.8544912","DOIUrl":null,"url":null,"abstract":"Gas insulated metal enclosed transmission line (GIL) is widely used in power transmission because of its prefect security and reliability. Tir-post insulator is one of the most important component in GIL which supports the insulation and structure. However, defects of tri-post insulator will distort the electric field distribution, weakened the insulation, even cause the insulation failure. The safety will be threatened by the defects. So it necessary to analyze the effect law of the electrical field distribution by defects, and focus on the severe place which is in the most need to avoid defects in production process. In this paper, a part of GIL model was built by using COMSOL Multiphysics which included the tri-post insulator. Two kinds of linear defects which may easily occur on tri-post insulator were researched. Result shows that the linear defects have different influence on electric field distribution in varying degree and indicates the effect laws of distortion with position and size of defects.","PeriodicalId":377544,"journal":{"name":"2018 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","volume":"23 3","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Study on Electric Field Distortion Effect by Linear Defects of Tri-post Insulator\",\"authors\":\"Zehua Wu, Haoran Wang, H. Tian, B. Cui, Shiyi Zhou, Zongren Peng\",\"doi\":\"10.1109/CEIDP.2018.8544912\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Gas insulated metal enclosed transmission line (GIL) is widely used in power transmission because of its prefect security and reliability. Tir-post insulator is one of the most important component in GIL which supports the insulation and structure. However, defects of tri-post insulator will distort the electric field distribution, weakened the insulation, even cause the insulation failure. The safety will be threatened by the defects. So it necessary to analyze the effect law of the electrical field distribution by defects, and focus on the severe place which is in the most need to avoid defects in production process. In this paper, a part of GIL model was built by using COMSOL Multiphysics which included the tri-post insulator. Two kinds of linear defects which may easily occur on tri-post insulator were researched. Result shows that the linear defects have different influence on electric field distribution in varying degree and indicates the effect laws of distortion with position and size of defects.\",\"PeriodicalId\":377544,\"journal\":{\"name\":\"2018 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)\",\"volume\":\"23 3\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2018.8544912\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2018.8544912","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

气体绝缘金属封闭输电线路由于具有良好的安全性和可靠性,在电力传输中得到了广泛的应用。铁柱绝缘子是GIL中最重要的支撑绝缘和支撑结构的部件之一。然而,三柱绝缘子的缺陷会使电场分布发生扭曲,使绝缘层变弱,甚至导致绝缘层失效。安全将受到缺陷的威胁。因此,有必要分析缺陷对电场分布的影响规律,重点关注生产过程中最需要避免缺陷的严重部位。本文利用COMSOL Multiphysics软件建立了包括三柱绝缘子在内的部分GIL模型。研究了三柱绝缘子易出现的两种线形缺陷。结果表明,线状缺陷对电场分布有不同程度的影响,并指出了畸变随缺陷位置和尺寸的影响规律。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study on Electric Field Distortion Effect by Linear Defects of Tri-post Insulator
Gas insulated metal enclosed transmission line (GIL) is widely used in power transmission because of its prefect security and reliability. Tir-post insulator is one of the most important component in GIL which supports the insulation and structure. However, defects of tri-post insulator will distort the electric field distribution, weakened the insulation, even cause the insulation failure. The safety will be threatened by the defects. So it necessary to analyze the effect law of the electrical field distribution by defects, and focus on the severe place which is in the most need to avoid defects in production process. In this paper, a part of GIL model was built by using COMSOL Multiphysics which included the tri-post insulator. Two kinds of linear defects which may easily occur on tri-post insulator were researched. Result shows that the linear defects have different influence on electric field distribution in varying degree and indicates the effect laws of distortion with position and size of defects.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信