采用90 GHz和140 GHz低温接收模块的机载成像系统

B. Vowinkel, K. Gruner, H. Suss, W. Reinert
{"title":"采用90 GHz和140 GHz低温接收模块的机载成像系统","authors":"B. Vowinkel, K. Gruner, H. Suss, W. Reinert","doi":"10.1109/EUMA.1983.333271","DOIUrl":null,"url":null,"abstract":"A high-resolution airborne imaging system has been developed that uses cryogenic receiver modules at 90 and 140 GHz. They consist of Schottky-barrier mixers followed by GaAs-FET IF amplifiers. The DSB receiver noise temperatures are 210 K for the 90 GHz and 250 K for the 140 GHz system. The instantaneous bandwidth is 2.5 GHz for both front-ends. Results of some flight tests are presented.","PeriodicalId":105436,"journal":{"name":"1983 13th European Microwave Conference","volume":"22 4","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1983-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Airborne Imaging System using Cryogenic Receiver Modules at 90 and 140 GHz\",\"authors\":\"B. Vowinkel, K. Gruner, H. Suss, W. Reinert\",\"doi\":\"10.1109/EUMA.1983.333271\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A high-resolution airborne imaging system has been developed that uses cryogenic receiver modules at 90 and 140 GHz. They consist of Schottky-barrier mixers followed by GaAs-FET IF amplifiers. The DSB receiver noise temperatures are 210 K for the 90 GHz and 250 K for the 140 GHz system. The instantaneous bandwidth is 2.5 GHz for both front-ends. Results of some flight tests are presented.\",\"PeriodicalId\":105436,\"journal\":{\"name\":\"1983 13th European Microwave Conference\",\"volume\":\"22 4\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1983-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1983 13th European Microwave Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EUMA.1983.333271\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1983 13th European Microwave Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUMA.1983.333271","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

采用90 GHz和140 GHz低温接收模块的高分辨率机载成像系统已经开发出来。它们由肖特基势垒混频器和GaAs-FET中频放大器组成。DSB接收机噪声温度在90 GHz和140 GHz系统分别为210 K和250 K。两个前端的瞬时带宽均为2.5 GHz。介绍了一些飞行试验的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Airborne Imaging System using Cryogenic Receiver Modules at 90 and 140 GHz
A high-resolution airborne imaging system has been developed that uses cryogenic receiver modules at 90 and 140 GHz. They consist of Schottky-barrier mixers followed by GaAs-FET IF amplifiers. The DSB receiver noise temperatures are 210 K for the 90 GHz and 250 K for the 140 GHz system. The instantaneous bandwidth is 2.5 GHz for both front-ends. Results of some flight tests are presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信