Dorian Haci, A. Mifsud, Yan Liu, S. Ghoreishizadeh, T. Constandinou
{"title":"多模块可植入微系统的体内有线接口平台","authors":"Dorian Haci, A. Mifsud, Yan Liu, S. Ghoreishizadeh, T. Constandinou","doi":"10.1109/BIOCAS.2019.8918756","DOIUrl":null,"url":null,"abstract":"The recent evolution of implantable medical devices from single-unit stimulators to modern implantable microsystems, has driven the need for distributed technologies, in which both the implant system and functions are partitioned across multiple active devices. This multi-module approach is made possible thanks to novel network architectures, allowing for in-body power and data communications to be performed using implantable leads. This paper discusses the challenges in implementing such interfacing system and presents a platform based on one central implant (CI) and multiple peripheral implants (PIs) using a custom 4WiCS communication protocol. This is implemented in PCB technology and tested to demonstrate intrabody communication capabilities and power transfer within the network. Measured results show CI-to-PI power delivery achieves 70 % efficiency in expected load condition, while establishing full-duplex data link with up to 4 PIs simultaneously.","PeriodicalId":222264,"journal":{"name":"2019 IEEE Biomedical Circuits and Systems Conference (BioCAS)","volume":"135 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In-body wireline interfacing platform for multi-module implantable microsystems\",\"authors\":\"Dorian Haci, A. Mifsud, Yan Liu, S. Ghoreishizadeh, T. Constandinou\",\"doi\":\"10.1109/BIOCAS.2019.8918756\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The recent evolution of implantable medical devices from single-unit stimulators to modern implantable microsystems, has driven the need for distributed technologies, in which both the implant system and functions are partitioned across multiple active devices. This multi-module approach is made possible thanks to novel network architectures, allowing for in-body power and data communications to be performed using implantable leads. This paper discusses the challenges in implementing such interfacing system and presents a platform based on one central implant (CI) and multiple peripheral implants (PIs) using a custom 4WiCS communication protocol. This is implemented in PCB technology and tested to demonstrate intrabody communication capabilities and power transfer within the network. Measured results show CI-to-PI power delivery achieves 70 % efficiency in expected load condition, while establishing full-duplex data link with up to 4 PIs simultaneously.\",\"PeriodicalId\":222264,\"journal\":{\"name\":\"2019 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"volume\":\"135 \",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOCAS.2019.8918756\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2019.8918756","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
In-body wireline interfacing platform for multi-module implantable microsystems
The recent evolution of implantable medical devices from single-unit stimulators to modern implantable microsystems, has driven the need for distributed technologies, in which both the implant system and functions are partitioned across multiple active devices. This multi-module approach is made possible thanks to novel network architectures, allowing for in-body power and data communications to be performed using implantable leads. This paper discusses the challenges in implementing such interfacing system and presents a platform based on one central implant (CI) and multiple peripheral implants (PIs) using a custom 4WiCS communication protocol. This is implemented in PCB technology and tested to demonstrate intrabody communication capabilities and power transfer within the network. Measured results show CI-to-PI power delivery achieves 70 % efficiency in expected load condition, while establishing full-duplex data link with up to 4 PIs simultaneously.