{"title":"利用多个测量值之间的相干性滤波噪声频率测量值","authors":"K. Dey, A. Kulkarni","doi":"10.1109/NPSC.2018.8771857","DOIUrl":null,"url":null,"abstract":"Distributed energy sources that are interfaced to the grid using power electronic converters and are connected to the medium and low voltage network, can potentially play an important role in improving the electro-mechanical stability of a grid. The bus frequency signal is the most convenient local feedback signal that can be used for this purpose. The bus voltage in a distribution system can be significantly distorted; therefore the frequency measurements are noisy and require heavy filtering. In this paper we propose the use of coherence functions of measurements taken at multiple locations to design the parameters (in non real-time) that result in very low phase delay. The filter designed using this method is found to be resilient to sudden spurious data (periodic spikes or glitches). The filtering algorithm has been tested on the real-life distribution system frequency measurements of the Indian grid.","PeriodicalId":185930,"journal":{"name":"2018 20th National Power Systems Conference (NPSC)","volume":"41 ","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Filtering of Noisy Frequency Measurements Using Coherence between Multiple Measurements\",\"authors\":\"K. Dey, A. Kulkarni\",\"doi\":\"10.1109/NPSC.2018.8771857\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Distributed energy sources that are interfaced to the grid using power electronic converters and are connected to the medium and low voltage network, can potentially play an important role in improving the electro-mechanical stability of a grid. The bus frequency signal is the most convenient local feedback signal that can be used for this purpose. The bus voltage in a distribution system can be significantly distorted; therefore the frequency measurements are noisy and require heavy filtering. In this paper we propose the use of coherence functions of measurements taken at multiple locations to design the parameters (in non real-time) that result in very low phase delay. The filter designed using this method is found to be resilient to sudden spurious data (periodic spikes or glitches). The filtering algorithm has been tested on the real-life distribution system frequency measurements of the Indian grid.\",\"PeriodicalId\":185930,\"journal\":{\"name\":\"2018 20th National Power Systems Conference (NPSC)\",\"volume\":\"41 \",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 20th National Power Systems Conference (NPSC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NPSC.2018.8771857\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 20th National Power Systems Conference (NPSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NPSC.2018.8771857","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

使用电力电子转换器与电网连接并连接到中低压电网的分布式能源,可能在提高电网的机电稳定性方面发挥重要作用。总线频率信号是最方便的本地反馈信号,可用于此目的。配电系统中的母线电压会发生明显的畸变;因此,频率测量是有噪声的,需要进行大量滤波。在本文中,我们提出使用在多个位置测量的相干函数来设计参数(非实时),从而导致非常低的相位延迟。使用这种方法设计的滤波器对突然的杂散数据(周期性尖峰或故障)具有弹性。该滤波算法已在印度电网的实际配电系统频率测量中进行了测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Filtering of Noisy Frequency Measurements Using Coherence between Multiple Measurements
Distributed energy sources that are interfaced to the grid using power electronic converters and are connected to the medium and low voltage network, can potentially play an important role in improving the electro-mechanical stability of a grid. The bus frequency signal is the most convenient local feedback signal that can be used for this purpose. The bus voltage in a distribution system can be significantly distorted; therefore the frequency measurements are noisy and require heavy filtering. In this paper we propose the use of coherence functions of measurements taken at multiple locations to design the parameters (in non real-time) that result in very low phase delay. The filter designed using this method is found to be resilient to sudden spurious data (periodic spikes or glitches). The filtering algorithm has been tested on the real-life distribution system frequency measurements of the Indian grid.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信