{"title":"孤岛检测中的阻抗估计和总谐波失真方法","authors":"Bohan Liu, K. Jia","doi":"10.1109/ICRERA.2012.6477473","DOIUrl":null,"url":null,"abstract":"An islanding situation should be detected accurately soon after the island is formed. Because failure to trip the islanded distributed resource can lead to a number of problems for the resource and the connected load. Therefore, it is important to distinguish islanding and non-islanding situations and block the nuisance tripping effectively. This paper compares two islanding detection methods, during the load variation (non-islanding) and power imbalance closely match (islanding) conditions, the performance of these two methods are investigated.","PeriodicalId":239142,"journal":{"name":"2012 International Conference on Renewable Energy Research and Applications (ICRERA)","volume":"6 3","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Impedance Estimation and the Total Harmonic Distortion Methods for Islanding Detection\",\"authors\":\"Bohan Liu, K. Jia\",\"doi\":\"10.1109/ICRERA.2012.6477473\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An islanding situation should be detected accurately soon after the island is formed. Because failure to trip the islanded distributed resource can lead to a number of problems for the resource and the connected load. Therefore, it is important to distinguish islanding and non-islanding situations and block the nuisance tripping effectively. This paper compares two islanding detection methods, during the load variation (non-islanding) and power imbalance closely match (islanding) conditions, the performance of these two methods are investigated.\",\"PeriodicalId\":239142,\"journal\":{\"name\":\"2012 International Conference on Renewable Energy Research and Applications (ICRERA)\",\"volume\":\"6 3\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Renewable Energy Research and Applications (ICRERA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICRERA.2012.6477473\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Renewable Energy Research and Applications (ICRERA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICRERA.2012.6477473","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Impedance Estimation and the Total Harmonic Distortion Methods for Islanding Detection
An islanding situation should be detected accurately soon after the island is formed. Because failure to trip the islanded distributed resource can lead to a number of problems for the resource and the connected load. Therefore, it is important to distinguish islanding and non-islanding situations and block the nuisance tripping effectively. This paper compares two islanding detection methods, during the load variation (non-islanding) and power imbalance closely match (islanding) conditions, the performance of these two methods are investigated.