PMU和PDC服务器实现集成到实时仿真工具

David F. Celeita, Diego Clavijo, G. Ramos
{"title":"PMU和PDC服务器实现集成到实时仿真工具","authors":"David F. Celeita, Diego Clavijo, G. Ramos","doi":"10.1109/PEPQA.2019.8851546","DOIUrl":null,"url":null,"abstract":"The use of real-time simulation tools brings several possibilities for improving testing and prototype assessment with higher precision and ensuring reliability in the study of power systems. This paper shows the design and implementation of a phasor measurement unit (PMU) in conjunction with synchronized phasor data concentrator (PDC software) to measure electrical parameters within a running real-time simulation of a power system. The system’s performance is evaluated under different scenarios to ensure standardized features of the virtual PMU and check consistent data collected by the PDC. A real case study of the Colombian transmission system is implemented. Finally, future applications and possibilities that can be developed with this platform are described.","PeriodicalId":192905,"journal":{"name":"2019 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)","volume":"149 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"PMU and PDC server implementation integrated to real-time simulation tools\",\"authors\":\"David F. Celeita, Diego Clavijo, G. Ramos\",\"doi\":\"10.1109/PEPQA.2019.8851546\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The use of real-time simulation tools brings several possibilities for improving testing and prototype assessment with higher precision and ensuring reliability in the study of power systems. This paper shows the design and implementation of a phasor measurement unit (PMU) in conjunction with synchronized phasor data concentrator (PDC software) to measure electrical parameters within a running real-time simulation of a power system. The system’s performance is evaluated under different scenarios to ensure standardized features of the virtual PMU and check consistent data collected by the PDC. A real case study of the Colombian transmission system is implemented. Finally, future applications and possibilities that can be developed with this platform are described.\",\"PeriodicalId\":192905,\"journal\":{\"name\":\"2019 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)\",\"volume\":\"149 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEPQA.2019.8851546\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEPQA.2019.8851546","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

实时仿真工具的使用为提高测试和原型评估的精度以及确保电力系统研究的可靠性提供了多种可能性。本文介绍了相量测量单元(PMU)与同步相量数据集中器(PDC软件)的设计和实现,以测量电力系统运行中的实时仿真中的电气参数。通过在不同场景下对系统进行性能评估,确保虚拟PMU功能的标准化,并检查配电柜采集数据的一致性。对哥伦比亚输电系统进行了实际案例研究。最后,描述了该平台未来的应用和开发可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
PMU and PDC server implementation integrated to real-time simulation tools
The use of real-time simulation tools brings several possibilities for improving testing and prototype assessment with higher precision and ensuring reliability in the study of power systems. This paper shows the design and implementation of a phasor measurement unit (PMU) in conjunction with synchronized phasor data concentrator (PDC software) to measure electrical parameters within a running real-time simulation of a power system. The system’s performance is evaluated under different scenarios to ensure standardized features of the virtual PMU and check consistent data collected by the PDC. A real case study of the Colombian transmission system is implemented. Finally, future applications and possibilities that can be developed with this platform are described.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信