用于检测生物膜稳定性的自组装微型spr

Shan Tang, Yunlong Wei
{"title":"用于检测生物膜稳定性的自组装微型spr","authors":"Shan Tang, Yunlong Wei","doi":"10.1117/12.784377","DOIUrl":null,"url":null,"abstract":"Supported Bilayer Lipid Membrane (s-BLM) affords a great direction to study the lipid membrane. It becomes a key to study the stability of s-BLM. The study is adopting a method with optics to detect data not electronics, because it can avoid the disturbance which is brought by the electric charge. Based on the basic principles of SPR, we assembled a mini-SPR equipment, and it has the accuracy fitting for our works. To adjust the angle of the polarizer and move the fiber, we can make the spectrogram that membrane is coupled on the surface of the gold slice. Comparing to the reference spectrogram, we can make a certain relationship between the light absorbed maximum and the quality of the phospholipid molecules coupling on the surface. It can token the resident time with the time which the detected spectrogram resumes to the reference one. And the resonance angle has a definite shift. We can assess the stability of phospholipid BLM with the three references. The mini-SPR equipment can easily change the parts and the parameter with the up-and-down equipment, the movement of the fiber and replacing the triangular prism plated the thin metal. So we can explore and find the conditions of the stability of BLM effectively with it[1].","PeriodicalId":250590,"journal":{"name":"ICMIT: Mechatronics and Information Technology","volume":"2 2","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Self-assembled mini-SPR for detecting the stability of the bio-membrane\",\"authors\":\"Shan Tang, Yunlong Wei\",\"doi\":\"10.1117/12.784377\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Supported Bilayer Lipid Membrane (s-BLM) affords a great direction to study the lipid membrane. It becomes a key to study the stability of s-BLM. The study is adopting a method with optics to detect data not electronics, because it can avoid the disturbance which is brought by the electric charge. Based on the basic principles of SPR, we assembled a mini-SPR equipment, and it has the accuracy fitting for our works. To adjust the angle of the polarizer and move the fiber, we can make the spectrogram that membrane is coupled on the surface of the gold slice. Comparing to the reference spectrogram, we can make a certain relationship between the light absorbed maximum and the quality of the phospholipid molecules coupling on the surface. It can token the resident time with the time which the detected spectrogram resumes to the reference one. And the resonance angle has a definite shift. We can assess the stability of phospholipid BLM with the three references. The mini-SPR equipment can easily change the parts and the parameter with the up-and-down equipment, the movement of the fiber and replacing the triangular prism plated the thin metal. So we can explore and find the conditions of the stability of BLM effectively with it[1].\",\"PeriodicalId\":250590,\"journal\":{\"name\":\"ICMIT: Mechatronics and Information Technology\",\"volume\":\"2 2\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-12-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ICMIT: Mechatronics and Information Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1117/12.784377\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICMIT: Mechatronics and Information Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.784377","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

支撑双层脂质膜(s-BLM)为脂质膜的研究提供了一个很好的方向。这成为研究s-BLM稳定性的关键。本研究采用光学而非电子学的方法来检测数据,因为这样可以避免电荷带来的干扰。根据SPR的基本原理,我们组装了一个小型SPR设备,它的精度适合我们的工作。通过调整偏振片的角度和移动光纤,可以得到薄膜耦合在金片表面的光谱图。通过对比参考谱图,我们可以得出最大吸收光量与表面磷脂分子耦合质量之间存在一定的关系。它可以用检测到的谱图恢复到参考谱图的时间来表示驻留时间。共振角有一个明显的位移。我们可以通过这三个参考文献来评价磷脂BLM的稳定性。小型spr设备可以方便地改变零件和参数,通过上下设备,光纤的运动和更换镀薄金属的三角棱镜。因此,利用b[1]可以有效地探索和寻找BLM稳定的条件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Self-assembled mini-SPR for detecting the stability of the bio-membrane
Supported Bilayer Lipid Membrane (s-BLM) affords a great direction to study the lipid membrane. It becomes a key to study the stability of s-BLM. The study is adopting a method with optics to detect data not electronics, because it can avoid the disturbance which is brought by the electric charge. Based on the basic principles of SPR, we assembled a mini-SPR equipment, and it has the accuracy fitting for our works. To adjust the angle of the polarizer and move the fiber, we can make the spectrogram that membrane is coupled on the surface of the gold slice. Comparing to the reference spectrogram, we can make a certain relationship between the light absorbed maximum and the quality of the phospholipid molecules coupling on the surface. It can token the resident time with the time which the detected spectrogram resumes to the reference one. And the resonance angle has a definite shift. We can assess the stability of phospholipid BLM with the three references. The mini-SPR equipment can easily change the parts and the parameter with the up-and-down equipment, the movement of the fiber and replacing the triangular prism plated the thin metal. So we can explore and find the conditions of the stability of BLM effectively with it[1].
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信