使用迭代重建的小动物PET心脏动态图像部分体积校正:对葡萄糖代谢率测量的影响

D. D'Ambrosio, G. Fiacchi, P. Cilibrizzi, C. Lamberti, G. Baldazzi, S. Boschi, R. Franchi, M. Marengo, A. Spinelli
{"title":"使用迭代重建的小动物PET心脏动态图像部分体积校正:对葡萄糖代谢率测量的影响","authors":"D. D'Ambrosio, G. Fiacchi, P. Cilibrizzi, C. Lamberti, G. Baldazzi, S. Boschi, R. Franchi, M. Marengo, A. Spinelli","doi":"10.1109/CIC.2008.4749236","DOIUrl":null,"url":null,"abstract":"Small animal positron emission tomography (PET) image quantitation is severely affected by partial volume effect (PVE) caused by the spatial resolution of PET tomographs. The aim of this work was to reduce the PVE using a modified iterative expectation maximization (EM) reconstruction algorithm. The goal of the method was to increase the accuracy of tracer concentration values in order to obtain an in vivo better estimate of physiological parameters. The performance of the proposed correction method was evaluated by calculating left ventricle and myocardium mean value using simulated cardiac fluorodeoxyglucose (FDG) dynamic images.","PeriodicalId":194782,"journal":{"name":"2008 Computers in Cardiology","volume":"49 3","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Partial volume correction of small animal PET cardiac dynamic images using iterative reconstruction: effects on glucose metabolic rate measurement\",\"authors\":\"D. D'Ambrosio, G. Fiacchi, P. Cilibrizzi, C. Lamberti, G. Baldazzi, S. Boschi, R. Franchi, M. Marengo, A. Spinelli\",\"doi\":\"10.1109/CIC.2008.4749236\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Small animal positron emission tomography (PET) image quantitation is severely affected by partial volume effect (PVE) caused by the spatial resolution of PET tomographs. The aim of this work was to reduce the PVE using a modified iterative expectation maximization (EM) reconstruction algorithm. The goal of the method was to increase the accuracy of tracer concentration values in order to obtain an in vivo better estimate of physiological parameters. The performance of the proposed correction method was evaluated by calculating left ventricle and myocardium mean value using simulated cardiac fluorodeoxyglucose (FDG) dynamic images.\",\"PeriodicalId\":194782,\"journal\":{\"name\":\"2008 Computers in Cardiology\",\"volume\":\"49 3\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Computers in Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.2008.4749236\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Computers in Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2008.4749236","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

小动物正电子发射断层扫描(PET)成像的空间分辨率导致的部分体积效应(PVE)严重影响其定量。本工作的目的是使用改进的迭代期望最大化(EM)重建算法来降低PVE。该方法的目的是提高示踪剂浓度值的准确性,以便更好地估计体内的生理参数。通过模拟心脏氟脱氧葡萄糖(FDG)动态图像计算左心室和心肌平均值来评估所提出的校正方法的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Partial volume correction of small animal PET cardiac dynamic images using iterative reconstruction: effects on glucose metabolic rate measurement
Small animal positron emission tomography (PET) image quantitation is severely affected by partial volume effect (PVE) caused by the spatial resolution of PET tomographs. The aim of this work was to reduce the PVE using a modified iterative expectation maximization (EM) reconstruction algorithm. The goal of the method was to increase the accuracy of tracer concentration values in order to obtain an in vivo better estimate of physiological parameters. The performance of the proposed correction method was evaluated by calculating left ventricle and myocardium mean value using simulated cardiac fluorodeoxyglucose (FDG) dynamic images.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信