完全植入式定向多普勒流量计。

Biotelemetry and patient monitoring Pub Date : 1979-01-01
H V Allen, J W Knutti, J D Meindl
{"title":"完全植入式定向多普勒流量计。","authors":"H V Allen,&nbsp;J W Knutti,&nbsp;J D Meindl","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Two totally implantable Doppler blood flowmeters have been developed for the chronic measurement of deep-body flows; made possibly by two custom-integrated circuits. The CW and pulsed Doppler instruments are small (less than 2.5 cm3), use little power (less than 30 mW), and have excellent baseline stability. The pulsed Doppler flowmeter is applied principally when velocity-profile information or a nonencircling transducer assembly is required but where minimal restraint of the animal for inductive telemetry is permissible. Using a circumferential cuff, the CW Doppler flowmeter monitors Doppler data over a at least a 3-meter range by means of RF telemetry and produces a single velocity estimate. These instruments compliment each other and other telemetry systems by proving the researcher with alternatives for the long-term measurement of deep-body flow without percutaneous leads.</p>","PeriodicalId":75603,"journal":{"name":"Biotelemetry and patient monitoring","volume":"6 3","pages":"118-32"},"PeriodicalIF":0.0000,"publicationDate":"1979-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Totally implantable directional Doppler flowmeters.\",\"authors\":\"H V Allen,&nbsp;J W Knutti,&nbsp;J D Meindl\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Two totally implantable Doppler blood flowmeters have been developed for the chronic measurement of deep-body flows; made possibly by two custom-integrated circuits. The CW and pulsed Doppler instruments are small (less than 2.5 cm3), use little power (less than 30 mW), and have excellent baseline stability. The pulsed Doppler flowmeter is applied principally when velocity-profile information or a nonencircling transducer assembly is required but where minimal restraint of the animal for inductive telemetry is permissible. Using a circumferential cuff, the CW Doppler flowmeter monitors Doppler data over a at least a 3-meter range by means of RF telemetry and produces a single velocity estimate. These instruments compliment each other and other telemetry systems by proving the researcher with alternatives for the long-term measurement of deep-body flow without percutaneous leads.</p>\",\"PeriodicalId\":75603,\"journal\":{\"name\":\"Biotelemetry and patient monitoring\",\"volume\":\"6 3\",\"pages\":\"118-32\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1979-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biotelemetry and patient monitoring\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotelemetry and patient monitoring","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

两种完全植入式多普勒血流仪已被开发用于慢性深部血流测量;可能由两个定制集成电路制造。连续波和脉冲多普勒仪器体积小(小于2.5 cm3),功率小(小于30 mW),基线稳定性好。脉冲多普勒流量计主要应用于需要速度剖面信息或非环绕传感器组件,但允许对动物进行感应遥测的最小约束的情况。采用环向袖带,连续波多普勒流量计通过射频遥测技术监测至少3米范围内的多普勒数据,并产生单次流速估计。这些仪器和其他遥测系统相互补充,为研究人员提供了无需经皮导联长期测量身体深部血流的替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Totally implantable directional Doppler flowmeters.

Two totally implantable Doppler blood flowmeters have been developed for the chronic measurement of deep-body flows; made possibly by two custom-integrated circuits. The CW and pulsed Doppler instruments are small (less than 2.5 cm3), use little power (less than 30 mW), and have excellent baseline stability. The pulsed Doppler flowmeter is applied principally when velocity-profile information or a nonencircling transducer assembly is required but where minimal restraint of the animal for inductive telemetry is permissible. Using a circumferential cuff, the CW Doppler flowmeter monitors Doppler data over a at least a 3-meter range by means of RF telemetry and produces a single velocity estimate. These instruments compliment each other and other telemetry systems by proving the researcher with alternatives for the long-term measurement of deep-body flow without percutaneous leads.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信