Karolina Mitrzak, Michał Peller, Bartosz Krzowski, Cezary Maciejewski, Paweł Balsam, Michał Marchel, Marcin Grabowski, Piotr Lodziński
{"title":"对心房颤动患者进行高功率、短时间消融术的安全性和有效性:初步结果。","authors":"Karolina Mitrzak, Michał Peller, Bartosz Krzowski, Cezary Maciejewski, Paweł Balsam, Michał Marchel, Marcin Grabowski, Piotr Lodziński","doi":"10.5603/CJ.a2022.0118","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pulmonary vein isolation (PVI) is at the forefront of rhythm control strategies in patients with atrial fibrillation (AF). A very-high-power, short-duration (vHPSD) catheter, QDot MicroTM (Biosense Webster) was designed to improve the effectiveness of AF ablation within a shorter procedure time. The aim of this study was to compare the effectiveness and safety of PVI ablation between this vHPSD ablation mode and conventional ablation-index-guided ablation (ThermoCool Smarttouch SF catheter).</p><p><strong>Methods: </strong>This single-center, retrospective, observational study enrolled 108 patients with AF, referred for catheter ablation between December 16, 2019 and December 3, 2021. In 54 procedures (mean age: 58.0 ± 12.3; 66.67% male), a QDot MicroTM catheter was used (vHPSD-group), and 54 patients (mean age: 57.2 ± 11.8; 70.37% male) were treated with a ThermoCool SmarttouchTM SF catheter (AI-group). The primary endpoint was freedom from AF 3 months after ablation.</p><p><strong>Results: </strong>Atrial fibrillation was found to recur in 14.81% of patients in the vHPSD-group and in 31.48% of patients in the AI-group (p = 0.07). There was no difference in treatment-emergent adverse events between the two groups (6.3% vs. 0%; p = 0.10). One severe adverse event (a cerebral vascular accident) was observed in the vHPSD-group. The mean dose of remifentanil was reported to be lower during QDot MicroTM catheter-based PVI (p < 0.01). The vHPSD-based PVI was associated with shorter radiofrequency application time (p < 0.001), fluoroscopy time (p < 0.0001), and total procedure time (p < 0.0001).</p><p><strong>Conclusions: </strong>This study suggests vHPSD ablation is safe, can reduce the dosage of analgesics during significantly shorter procedures and may enhance the success rate of catheter-based PVI.</p>","PeriodicalId":9492,"journal":{"name":"Cardiology journal","volume":" ","pages":"603-611"},"PeriodicalIF":2.5000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11374326/pdf/","citationCount":"0","resultStr":"{\"title\":\"Safety and effectiveness of very-high-power, short-duration ablation in patients with atrial fibrillation: Preliminary results.\",\"authors\":\"Karolina Mitrzak, Michał Peller, Bartosz Krzowski, Cezary Maciejewski, Paweł Balsam, Michał Marchel, Marcin Grabowski, Piotr Lodziński\",\"doi\":\"10.5603/CJ.a2022.0118\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Pulmonary vein isolation (PVI) is at the forefront of rhythm control strategies in patients with atrial fibrillation (AF). A very-high-power, short-duration (vHPSD) catheter, QDot MicroTM (Biosense Webster) was designed to improve the effectiveness of AF ablation within a shorter procedure time. The aim of this study was to compare the effectiveness and safety of PVI ablation between this vHPSD ablation mode and conventional ablation-index-guided ablation (ThermoCool Smarttouch SF catheter).</p><p><strong>Methods: </strong>This single-center, retrospective, observational study enrolled 108 patients with AF, referred for catheter ablation between December 16, 2019 and December 3, 2021. In 54 procedures (mean age: 58.0 ± 12.3; 66.67% male), a QDot MicroTM catheter was used (vHPSD-group), and 54 patients (mean age: 57.2 ± 11.8; 70.37% male) were treated with a ThermoCool SmarttouchTM SF catheter (AI-group). The primary endpoint was freedom from AF 3 months after ablation.</p><p><strong>Results: </strong>Atrial fibrillation was found to recur in 14.81% of patients in the vHPSD-group and in 31.48% of patients in the AI-group (p = 0.07). There was no difference in treatment-emergent adverse events between the two groups (6.3% vs. 0%; p = 0.10). One severe adverse event (a cerebral vascular accident) was observed in the vHPSD-group. The mean dose of remifentanil was reported to be lower during QDot MicroTM catheter-based PVI (p < 0.01). The vHPSD-based PVI was associated with shorter radiofrequency application time (p < 0.001), fluoroscopy time (p < 0.0001), and total procedure time (p < 0.0001).</p><p><strong>Conclusions: </strong>This study suggests vHPSD ablation is safe, can reduce the dosage of analgesics during significantly shorter procedures and may enhance the success rate of catheter-based PVI.</p>\",\"PeriodicalId\":9492,\"journal\":{\"name\":\"Cardiology journal\",\"volume\":\" \",\"pages\":\"603-611\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11374326/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiology journal\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5603/CJ.a2022.0118\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/1/2 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5603/CJ.a2022.0118","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/2 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Safety and effectiveness of very-high-power, short-duration ablation in patients with atrial fibrillation: Preliminary results.
Background: Pulmonary vein isolation (PVI) is at the forefront of rhythm control strategies in patients with atrial fibrillation (AF). A very-high-power, short-duration (vHPSD) catheter, QDot MicroTM (Biosense Webster) was designed to improve the effectiveness of AF ablation within a shorter procedure time. The aim of this study was to compare the effectiveness and safety of PVI ablation between this vHPSD ablation mode and conventional ablation-index-guided ablation (ThermoCool Smarttouch SF catheter).
Methods: This single-center, retrospective, observational study enrolled 108 patients with AF, referred for catheter ablation between December 16, 2019 and December 3, 2021. In 54 procedures (mean age: 58.0 ± 12.3; 66.67% male), a QDot MicroTM catheter was used (vHPSD-group), and 54 patients (mean age: 57.2 ± 11.8; 70.37% male) were treated with a ThermoCool SmarttouchTM SF catheter (AI-group). The primary endpoint was freedom from AF 3 months after ablation.
Results: Atrial fibrillation was found to recur in 14.81% of patients in the vHPSD-group and in 31.48% of patients in the AI-group (p = 0.07). There was no difference in treatment-emergent adverse events between the two groups (6.3% vs. 0%; p = 0.10). One severe adverse event (a cerebral vascular accident) was observed in the vHPSD-group. The mean dose of remifentanil was reported to be lower during QDot MicroTM catheter-based PVI (p < 0.01). The vHPSD-based PVI was associated with shorter radiofrequency application time (p < 0.001), fluoroscopy time (p < 0.0001), and total procedure time (p < 0.0001).
Conclusions: This study suggests vHPSD ablation is safe, can reduce the dosage of analgesics during significantly shorter procedures and may enhance the success rate of catheter-based PVI.
期刊介绍:
Cardiology Journal is a scientific, peer-reviewed journal covering a broad spectrum of topics in cardiology. The journal has been published since 1994 and over the years it has become an internationally recognized journal of cardiological and medical community.
Cardiology Journal is the journal for practicing cardiologists, researchers, and young trainees benefiting from broad spectrum of useful educational content.