COVID-19 大流行期间学生教学中的无线手持聚焦超声:试点研究的初步结果1。

IF 2.1 4区 医学 Q3 HEMATOLOGY
Ulrich Kaiser, Ivor Dropco, Kathrin Reuthner, Michael Ertl, Hans Jürgen Schlitt, Wolfgang Herr, Christian Stroszczynski, Ernst Michael Jung
{"title":"COVID-19 大流行期间学生教学中的无线手持聚焦超声:试点研究的初步结果1。","authors":"Ulrich Kaiser, Ivor Dropco, Kathrin Reuthner, Michael Ertl, Hans Jürgen Schlitt, Wolfgang Herr, Christian Stroszczynski, Ernst Michael Jung","doi":"10.3233/CH-229104","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The study aim was to investigate the use of a novel device, the Vscan Air™, for rapidly and effectively performing ultrasound in student teaching during the COVID-19 pandemic.</p><p><strong>Material and methods: </strong>As part of the ultrasound practical course with integrated hands-on activity required by the regular medical curriculum, 100 medical students were instructed in the use of the Vscan Air™, including duplex mode. They then evaluated the quality of the ultrasound images obtained by the Vscan Air™ from previously selected organs.</p><p><strong>Results: </strong>100 students were interviewed (female n = 68, male n = 32; age >18 years n = 100). The rated image quality never fell below a mean of 3 for the examined organs and portal vein flow (liver 4,58; spleen 3,99; kidneys 4,29; aorta 4,16; Douglas/rectovesical space 4,14; portal vein 4,43; pancreas 3,53; Focused Assessment with Sonography for Trauma 4,38). Scores below 3 were found sporadically in ultrasounds of the spleen (n = 4), kidneys (n = 3), Douglas/rectovesical space (n = 2), and pancreas (n = 15). The liver was rated the lowest for 59 ratings. The portal vein was evaluated in 68 cases. The hepatic artery and hepatic veins could be also visualized in all 68 examinations. The aorta was evaluated in 62 cases.</p><p><strong>Conclusion: </strong>The Vscan Air™ technology offered adequate image quality and provided a new, fast and patient-oriented technique to support continuous ultrasound examinations and education of students, especially during a pandemic. Particularly noteworthy is the uncomplicated compliance with the required high level of hygiene.</p>","PeriodicalId":10425,"journal":{"name":"Clinical hemorheology and microcirculation","volume":null,"pages":null},"PeriodicalIF":2.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Wireless handheld focused ultrasound in student teaching during the COVID-19 pandemic: Initial results of a pilot study1.\",\"authors\":\"Ulrich Kaiser, Ivor Dropco, Kathrin Reuthner, Michael Ertl, Hans Jürgen Schlitt, Wolfgang Herr, Christian Stroszczynski, Ernst Michael Jung\",\"doi\":\"10.3233/CH-229104\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The study aim was to investigate the use of a novel device, the Vscan Air™, for rapidly and effectively performing ultrasound in student teaching during the COVID-19 pandemic.</p><p><strong>Material and methods: </strong>As part of the ultrasound practical course with integrated hands-on activity required by the regular medical curriculum, 100 medical students were instructed in the use of the Vscan Air™, including duplex mode. They then evaluated the quality of the ultrasound images obtained by the Vscan Air™ from previously selected organs.</p><p><strong>Results: </strong>100 students were interviewed (female n = 68, male n = 32; age >18 years n = 100). The rated image quality never fell below a mean of 3 for the examined organs and portal vein flow (liver 4,58; spleen 3,99; kidneys 4,29; aorta 4,16; Douglas/rectovesical space 4,14; portal vein 4,43; pancreas 3,53; Focused Assessment with Sonography for Trauma 4,38). Scores below 3 were found sporadically in ultrasounds of the spleen (n = 4), kidneys (n = 3), Douglas/rectovesical space (n = 2), and pancreas (n = 15). The liver was rated the lowest for 59 ratings. The portal vein was evaluated in 68 cases. The hepatic artery and hepatic veins could be also visualized in all 68 examinations. The aorta was evaluated in 62 cases.</p><p><strong>Conclusion: </strong>The Vscan Air™ technology offered adequate image quality and provided a new, fast and patient-oriented technique to support continuous ultrasound examinations and education of students, especially during a pandemic. Particularly noteworthy is the uncomplicated compliance with the required high level of hygiene.</p>\",\"PeriodicalId\":10425,\"journal\":{\"name\":\"Clinical hemorheology and microcirculation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical hemorheology and microcirculation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3233/CH-229104\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical hemorheology and microcirculation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3233/CH-229104","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 3

摘要

研究目的研究目的是调查在 COVID-19 大流行期间,在学生教学中使用新型设备 Vscan Air™ 快速、有效地进行超声波检查的情况:作为常规医学课程要求的综合实践活动超声实践课程的一部分,100 名医科学生接受了 Vscan Air™ 的使用指导,包括双工模式。然后,他们对 Vscan Air™ 从先前选定的器官获得的超声图像质量进行了评估:结果:共访问了 100 名学生(女生 68 人,男生 32 人;年龄大于 18 岁的学生 100 人)。所检查器官和门静脉血流的图像质量评分平均值从未低于 3(肝脏 4.58;脾脏 3.99;肾脏 4.29;主动脉 4.16;道格拉斯/直肠静脉间隙 4.14;门静脉 4.43;胰腺 3.53;创伤超声重点评估 4.38)。在脾脏(4 例)、肾脏(3 例)、道格拉斯/直肠间隙(2 例)和胰腺(15 例)的超声检查中,得分零星低于 3 分。在 59 个评分中,肝脏的评分最低。对 68 个病例的门静脉进行了评估。在所有 68 次检查中,肝动脉和肝静脉也都能被看到。对 62 个病例的主动脉进行了评估:Vscan Air™ 技术提供了足够的图像质量,并提供了一种新的、快速和以患者为导向的技术,以支持连续的超声检查和学生教育,尤其是在大流行病期间。尤其值得注意的是,该技术能够轻松满足高度卫生的要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Wireless handheld focused ultrasound in student teaching during the COVID-19 pandemic: Initial results of a pilot study1.

Objective: The study aim was to investigate the use of a novel device, the Vscan Air™, for rapidly and effectively performing ultrasound in student teaching during the COVID-19 pandemic.

Material and methods: As part of the ultrasound practical course with integrated hands-on activity required by the regular medical curriculum, 100 medical students were instructed in the use of the Vscan Air™, including duplex mode. They then evaluated the quality of the ultrasound images obtained by the Vscan Air™ from previously selected organs.

Results: 100 students were interviewed (female n = 68, male n = 32; age >18 years n = 100). The rated image quality never fell below a mean of 3 for the examined organs and portal vein flow (liver 4,58; spleen 3,99; kidneys 4,29; aorta 4,16; Douglas/rectovesical space 4,14; portal vein 4,43; pancreas 3,53; Focused Assessment with Sonography for Trauma 4,38). Scores below 3 were found sporadically in ultrasounds of the spleen (n = 4), kidneys (n = 3), Douglas/rectovesical space (n = 2), and pancreas (n = 15). The liver was rated the lowest for 59 ratings. The portal vein was evaluated in 68 cases. The hepatic artery and hepatic veins could be also visualized in all 68 examinations. The aorta was evaluated in 62 cases.

Conclusion: The Vscan Air™ technology offered adequate image quality and provided a new, fast and patient-oriented technique to support continuous ultrasound examinations and education of students, especially during a pandemic. Particularly noteworthy is the uncomplicated compliance with the required high level of hygiene.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.30
自引率
33.30%
发文量
170
期刊介绍: Clinical Hemorheology and Microcirculation, a peer-reviewed international scientific journal, serves as an aid to understanding the flow properties of blood and the relationship to normal and abnormal physiology. The rapidly expanding science of hemorheology concerns blood, its components and the blood vessels with which blood interacts. It includes perihemorheology, i.e., the rheology of fluid and structures in the perivascular and interstitial spaces as well as the lymphatic system. The clinical aspects include pathogenesis, symptomatology and diagnostic methods, and the fields of prophylaxis and therapy in all branches of medicine and surgery, pharmacology and drug research. The endeavour of the Editors-in-Chief and publishers of Clinical Hemorheology and Microcirculation is to bring together contributions from those working in various fields related to blood flow all over the world. The editors of Clinical Hemorheology and Microcirculation are from those countries in Europe, Asia, Australia and America where appreciable work in clinical hemorheology and microcirculation is being carried out. Each editor takes responsibility to decide on the acceptance of a manuscript. He is required to have the manuscript appraised by two referees and may be one of them himself. The executive editorial office, to which the manuscripts have been submitted, is responsible for rapid handling of the reviewing process. Clinical Hemorheology and Microcirculation accepts original papers, brief communications, mini-reports and letters to the Editors-in-Chief. Review articles, providing general views and new insights into related subjects, are regularly invited by the Editors-in-Chief. Proceedings of international and national conferences on clinical hemorheology (in original form or as abstracts) complete the range of editorial features.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信