呼吸速率-氧合指数预测重症监护室患者拔管后高流量鼻插管治疗失败:一项回顾性队列研究。

Q2 Medicine
Yuli V Fuentes, Katherine Carvajal, Santiago Cardona, Gina Sofia Montaño, Elsa D Ibáñez-Prada, Alirio Bastidas, Eder Caceres, Ricardo Buitrago, Marcela Poveda, Luis Felipe Reyes
{"title":"呼吸速率-氧合指数预测重症监护室患者拔管后高流量鼻插管治疗失败:一项回顾性队列研究。","authors":"Yuli V Fuentes,&nbsp;Katherine Carvajal,&nbsp;Santiago Cardona,&nbsp;Gina Sofia Montaño,&nbsp;Elsa D Ibáñez-Prada,&nbsp;Alirio Bastidas,&nbsp;Eder Caceres,&nbsp;Ricardo Buitrago,&nbsp;Marcela Poveda,&nbsp;Luis Felipe Reyes","doi":"10.5935/0103-507X.20220477-pt","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the applicability of the Respiratory Rate-Oxygenation Index to identify the risk of high-flow nasal cannula failure in post-extubation pneumonia patients.</p><p><strong>Methods: </strong>This was a 2-year retrospective observational study conducted in a reference hospital in Bogotá, Colombia. All patients in whom post-extubation high-flow nasal cannula therapy was used as a bridge to extubation were included in the study. The Respiratory Rate-Oxygenation Index was calculated to assess the risk of post-extubation high-flow nasal cannula failure.</p><p><strong>Results: </strong>A total of 162 patients were included in the study. Of these, 23.5% developed high-flow nasal cannula failure. The Respiratory Rate-Oxygenation Index was significantly lower in patients who had high-flow nasal cannula failure [median (IQR): 10.0 (7.7 - 14.4) versus 12.6 (10.1 - 15.6); p = 0.006]. Respiratory Rate-Oxygenation Index > 4.88 showed a crude OR of 0.23 (95%CI 0.17 - 0.30) and an adjusted OR of 0.89 (95%CI 0.81 - 0.98) stratified by severity and comorbidity. After logistic regression analysis, the Respiratory Rate-Oxygenation Index had an adjusted OR of 0.90 (95%CI 0.82 - 0.98; p = 0.026). The area under the Receiver Operating Characteristic curve for extubation failure was 0.64 (95%CI 0.53 - 0.75; p = 0.06). The Respiratory Rate-Oxygenation Index did not show differences between patients who survived and those who died during the intensive care unit stay.</p><p><strong>Conclusion: </strong>The Respiratory Rate-Oxygenation Index is an accessible tool to identify patients at risk of failing high-flow nasal cannula post-extubation treatment. Prospective studies are needed to broaden the utility in this scenario.</p>","PeriodicalId":53519,"journal":{"name":"Revista Brasileira de Terapia Intensiva","volume":"34 3","pages":"360-366"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9749095/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Respiratory Rate-Oxygenation Index predicts failure of post-extubation high-flow nasal cannula therapy in intensive care unit patients: a retrospective cohort study.\",\"authors\":\"Yuli V Fuentes,&nbsp;Katherine Carvajal,&nbsp;Santiago Cardona,&nbsp;Gina Sofia Montaño,&nbsp;Elsa D Ibáñez-Prada,&nbsp;Alirio Bastidas,&nbsp;Eder Caceres,&nbsp;Ricardo Buitrago,&nbsp;Marcela Poveda,&nbsp;Luis Felipe Reyes\",\"doi\":\"10.5935/0103-507X.20220477-pt\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To investigate the applicability of the Respiratory Rate-Oxygenation Index to identify the risk of high-flow nasal cannula failure in post-extubation pneumonia patients.</p><p><strong>Methods: </strong>This was a 2-year retrospective observational study conducted in a reference hospital in Bogotá, Colombia. All patients in whom post-extubation high-flow nasal cannula therapy was used as a bridge to extubation were included in the study. The Respiratory Rate-Oxygenation Index was calculated to assess the risk of post-extubation high-flow nasal cannula failure.</p><p><strong>Results: </strong>A total of 162 patients were included in the study. Of these, 23.5% developed high-flow nasal cannula failure. The Respiratory Rate-Oxygenation Index was significantly lower in patients who had high-flow nasal cannula failure [median (IQR): 10.0 (7.7 - 14.4) versus 12.6 (10.1 - 15.6); p = 0.006]. Respiratory Rate-Oxygenation Index > 4.88 showed a crude OR of 0.23 (95%CI 0.17 - 0.30) and an adjusted OR of 0.89 (95%CI 0.81 - 0.98) stratified by severity and comorbidity. After logistic regression analysis, the Respiratory Rate-Oxygenation Index had an adjusted OR of 0.90 (95%CI 0.82 - 0.98; p = 0.026). The area under the Receiver Operating Characteristic curve for extubation failure was 0.64 (95%CI 0.53 - 0.75; p = 0.06). The Respiratory Rate-Oxygenation Index did not show differences between patients who survived and those who died during the intensive care unit stay.</p><p><strong>Conclusion: </strong>The Respiratory Rate-Oxygenation Index is an accessible tool to identify patients at risk of failing high-flow nasal cannula post-extubation treatment. Prospective studies are needed to broaden the utility in this scenario.</p>\",\"PeriodicalId\":53519,\"journal\":{\"name\":\"Revista Brasileira de Terapia Intensiva\",\"volume\":\"34 3\",\"pages\":\"360-366\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9749095/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Brasileira de Terapia Intensiva\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5935/0103-507X.20220477-pt\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira de Terapia Intensiva","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5935/0103-507X.20220477-pt","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:探讨呼吸速率-氧合指数在诊断拔管后肺炎患者高流量鼻插管失败风险中的适用性。方法:这是一项在哥伦比亚波哥大一家参考医院进行的为期2年的回顾性观察研究。所有拔管后使用高流量鼻插管治疗作为拔管桥梁的患者均纳入研究。计算呼吸速率-氧合指数以评估拔管后高流量鼻插管失败的风险。结果:共纳入162例患者。其中,23.5%出现高流量鼻插管失败。高流量鼻插管失败患者的呼吸速率-氧合指数显著降低[中位数(IQR): 10.0 (7.7 - 14.4) vs 12.6 (10.1 - 15.6);P = 0.006]。呼吸速率-氧合指数> 4.88,按严重程度和合并症分层,粗OR为0.23 (95%CI 0.17 ~ 0.30),调整OR为0.89 (95%CI 0.81 ~ 0.98)。经logistic回归分析,呼吸速率-氧合指数调整OR为0.90 (95%CI 0.82 ~ 0.98;P = 0.026)。拔管失败的受试者工作特征曲线下面积为0.64 (95%CI 0.53 ~ 0.75;P = 0.06)。呼吸速率-氧合指数在重症监护期间存活和死亡的患者之间没有显示差异。结论:呼吸速率-氧合指数是一种可识别高流量鼻插管拔管后治疗失败风险患者的工具。需要前瞻性研究来扩大在这种情况下的效用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

The Respiratory Rate-Oxygenation Index predicts failure of post-extubation high-flow nasal cannula therapy in intensive care unit patients: a retrospective cohort study.

The Respiratory Rate-Oxygenation Index predicts failure of post-extubation high-flow nasal cannula therapy in intensive care unit patients: a retrospective cohort study.

Objective: To investigate the applicability of the Respiratory Rate-Oxygenation Index to identify the risk of high-flow nasal cannula failure in post-extubation pneumonia patients.

Methods: This was a 2-year retrospective observational study conducted in a reference hospital in Bogotá, Colombia. All patients in whom post-extubation high-flow nasal cannula therapy was used as a bridge to extubation were included in the study. The Respiratory Rate-Oxygenation Index was calculated to assess the risk of post-extubation high-flow nasal cannula failure.

Results: A total of 162 patients were included in the study. Of these, 23.5% developed high-flow nasal cannula failure. The Respiratory Rate-Oxygenation Index was significantly lower in patients who had high-flow nasal cannula failure [median (IQR): 10.0 (7.7 - 14.4) versus 12.6 (10.1 - 15.6); p = 0.006]. Respiratory Rate-Oxygenation Index > 4.88 showed a crude OR of 0.23 (95%CI 0.17 - 0.30) and an adjusted OR of 0.89 (95%CI 0.81 - 0.98) stratified by severity and comorbidity. After logistic regression analysis, the Respiratory Rate-Oxygenation Index had an adjusted OR of 0.90 (95%CI 0.82 - 0.98; p = 0.026). The area under the Receiver Operating Characteristic curve for extubation failure was 0.64 (95%CI 0.53 - 0.75; p = 0.06). The Respiratory Rate-Oxygenation Index did not show differences between patients who survived and those who died during the intensive care unit stay.

Conclusion: The Respiratory Rate-Oxygenation Index is an accessible tool to identify patients at risk of failing high-flow nasal cannula post-extubation treatment. Prospective studies are needed to broaden the utility in this scenario.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Revista Brasileira de Terapia Intensiva
Revista Brasileira de Terapia Intensiva Medicine-Critical Care and Intensive Care Medicine
自引率
0.00%
发文量
114
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信