{"title":"在初次全膝关节置换术中,5mm金属块增强胫骨假体结构的稳定性并不是强制性的额外胫骨柄延伸:5年最小随访结果。","authors":"Jae Joon Ryu, Yeong Hwan Kim, Choong Hyeok Choi","doi":"10.1186/s43019-023-00174-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine whether additional stem extension for stability is necessary, we performed mid-term follow-up of patients who had been managed with 5-mm metal block augmentation for a tibial defect, where tibial prosthesis was fixed using bone cement without stem extension. Also, we evaluated clinical and radiologic results including survival rate of patients without stem extension.</p><p><strong>Methods: </strong>We retrospectively analyzed patients with tibial bone defect, had undergone primary total knee arthroplasty, and had been treated with 5-mm metal block augmentation without stem extension between March 2003 and September 2013. Among 74 patients (80 cases), 47 patients (52 cases) were followed up for at least 5 years.</p><p><strong>Results: </strong>Mean flexion contracture improved from 8.8° (0-40°) preoperatively to 0.4° (-5° to 15°) at final follow-up (P < 0.01), but there was no significant change in the mean angle of great flexion: 124.6° (75-150°) preoperatively and 126.2° (90-145°) at final follow-up (P = 0.488). Mean range of motion improved from 115.8° (35-150°) preoperatively to 125.5° (90-145°) at final follow-up (P < 0.01). Mean knee score improved from 38.7 points (0-66 points) preoperatively to 93.2 points (79-100 points) at final follow-up (P < 0.01), and mean functional score also improved from 50.4 points (10-70 points) preoperatively to 81.8 points (15-100 points) at final follow-up (P < 0.01). The mean postoperative Western Ontario and McMaster University osteoarthritis score was 19.5 points (0-66.0 points). The mean femorotibial angle was corrected from 9.0° varus (23.0° varus-6.3° valgus) preoperatively to 5.5° valgus (2.2° varus-11.1° valgus) at final follow-up (P < 0.01). There was no change in the mean β-angle, which was 90.7° (87.2-94.9°) immediately postoperative and 90.8° (87.2-94.9°) at final follow-up (P = 0.748) and in the mean δ-angle, which was 86.2° (81.3-90.0°) immediately postoperative and 87.2° (83.1-96.5°) at final follow-up (P = 0.272). Radiolucent lines (RLL) were observed in ten cases (26.3%), and the mean RLL scores at final follow-up were 0.34 points (0-3 points) in the anteroposterior view and 0.42 points (0-6 points) in the lateral view. Scores for the RLL were ≤ 4 points in 36 cases, 5-9 points in two cases. Revision surgery due to aseptic loosening (three cases) is rarely required, and the Kaplan-Meier survival rate at 10 postoperative years was 96.4% CONCLUSION: When performing 5-mm metal block augmentation for a proximal tibial defect, no additional tibial stem extension can be a good surgical option for the stability of tibial prosthetic construct and mid-term clinical and radiologic results.</p><p><strong>Level of evidence: </strong>IV.</p>","PeriodicalId":17886,"journal":{"name":"Knee Surgery & Related Research","volume":null,"pages":null},"PeriodicalIF":4.1000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9890779/pdf/","citationCount":"1","resultStr":"{\"title\":\"The additional tibial stem extension is not mandatory for the stability of 5 mm metal block augmented tibial prosthesis construct in primary total knee arthroplasty: 5-year minimum follow-up results.\",\"authors\":\"Jae Joon Ryu, Yeong Hwan Kim, Choong Hyeok Choi\",\"doi\":\"10.1186/s43019-023-00174-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To determine whether additional stem extension for stability is necessary, we performed mid-term follow-up of patients who had been managed with 5-mm metal block augmentation for a tibial defect, where tibial prosthesis was fixed using bone cement without stem extension. Also, we evaluated clinical and radiologic results including survival rate of patients without stem extension.</p><p><strong>Methods: </strong>We retrospectively analyzed patients with tibial bone defect, had undergone primary total knee arthroplasty, and had been treated with 5-mm metal block augmentation without stem extension between March 2003 and September 2013. Among 74 patients (80 cases), 47 patients (52 cases) were followed up for at least 5 years.</p><p><strong>Results: </strong>Mean flexion contracture improved from 8.8° (0-40°) preoperatively to 0.4° (-5° to 15°) at final follow-up (P < 0.01), but there was no significant change in the mean angle of great flexion: 124.6° (75-150°) preoperatively and 126.2° (90-145°) at final follow-up (P = 0.488). Mean range of motion improved from 115.8° (35-150°) preoperatively to 125.5° (90-145°) at final follow-up (P < 0.01). Mean knee score improved from 38.7 points (0-66 points) preoperatively to 93.2 points (79-100 points) at final follow-up (P < 0.01), and mean functional score also improved from 50.4 points (10-70 points) preoperatively to 81.8 points (15-100 points) at final follow-up (P < 0.01). The mean postoperative Western Ontario and McMaster University osteoarthritis score was 19.5 points (0-66.0 points). The mean femorotibial angle was corrected from 9.0° varus (23.0° varus-6.3° valgus) preoperatively to 5.5° valgus (2.2° varus-11.1° valgus) at final follow-up (P < 0.01). There was no change in the mean β-angle, which was 90.7° (87.2-94.9°) immediately postoperative and 90.8° (87.2-94.9°) at final follow-up (P = 0.748) and in the mean δ-angle, which was 86.2° (81.3-90.0°) immediately postoperative and 87.2° (83.1-96.5°) at final follow-up (P = 0.272). Radiolucent lines (RLL) were observed in ten cases (26.3%), and the mean RLL scores at final follow-up were 0.34 points (0-3 points) in the anteroposterior view and 0.42 points (0-6 points) in the lateral view. Scores for the RLL were ≤ 4 points in 36 cases, 5-9 points in two cases. Revision surgery due to aseptic loosening (three cases) is rarely required, and the Kaplan-Meier survival rate at 10 postoperative years was 96.4% CONCLUSION: When performing 5-mm metal block augmentation for a proximal tibial defect, no additional tibial stem extension can be a good surgical option for the stability of tibial prosthetic construct and mid-term clinical and radiologic results.</p><p><strong>Level of evidence: </strong>IV.</p>\",\"PeriodicalId\":17886,\"journal\":{\"name\":\"Knee Surgery & Related Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.1000,\"publicationDate\":\"2023-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9890779/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Knee Surgery & Related Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s43019-023-00174-6\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Knee Surgery & Related Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s43019-023-00174-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
The additional tibial stem extension is not mandatory for the stability of 5 mm metal block augmented tibial prosthesis construct in primary total knee arthroplasty: 5-year minimum follow-up results.
Purpose: To determine whether additional stem extension for stability is necessary, we performed mid-term follow-up of patients who had been managed with 5-mm metal block augmentation for a tibial defect, where tibial prosthesis was fixed using bone cement without stem extension. Also, we evaluated clinical and radiologic results including survival rate of patients without stem extension.
Methods: We retrospectively analyzed patients with tibial bone defect, had undergone primary total knee arthroplasty, and had been treated with 5-mm metal block augmentation without stem extension between March 2003 and September 2013. Among 74 patients (80 cases), 47 patients (52 cases) were followed up for at least 5 years.
Results: Mean flexion contracture improved from 8.8° (0-40°) preoperatively to 0.4° (-5° to 15°) at final follow-up (P < 0.01), but there was no significant change in the mean angle of great flexion: 124.6° (75-150°) preoperatively and 126.2° (90-145°) at final follow-up (P = 0.488). Mean range of motion improved from 115.8° (35-150°) preoperatively to 125.5° (90-145°) at final follow-up (P < 0.01). Mean knee score improved from 38.7 points (0-66 points) preoperatively to 93.2 points (79-100 points) at final follow-up (P < 0.01), and mean functional score also improved from 50.4 points (10-70 points) preoperatively to 81.8 points (15-100 points) at final follow-up (P < 0.01). The mean postoperative Western Ontario and McMaster University osteoarthritis score was 19.5 points (0-66.0 points). The mean femorotibial angle was corrected from 9.0° varus (23.0° varus-6.3° valgus) preoperatively to 5.5° valgus (2.2° varus-11.1° valgus) at final follow-up (P < 0.01). There was no change in the mean β-angle, which was 90.7° (87.2-94.9°) immediately postoperative and 90.8° (87.2-94.9°) at final follow-up (P = 0.748) and in the mean δ-angle, which was 86.2° (81.3-90.0°) immediately postoperative and 87.2° (83.1-96.5°) at final follow-up (P = 0.272). Radiolucent lines (RLL) were observed in ten cases (26.3%), and the mean RLL scores at final follow-up were 0.34 points (0-3 points) in the anteroposterior view and 0.42 points (0-6 points) in the lateral view. Scores for the RLL were ≤ 4 points in 36 cases, 5-9 points in two cases. Revision surgery due to aseptic loosening (three cases) is rarely required, and the Kaplan-Meier survival rate at 10 postoperative years was 96.4% CONCLUSION: When performing 5-mm metal block augmentation for a proximal tibial defect, no additional tibial stem extension can be a good surgical option for the stability of tibial prosthetic construct and mid-term clinical and radiologic results.