Omar Yusef Kudsi, Georges Kaoukabani, Naseem Bou-Ayash, Fahri Gokcal
{"title":"混合网片与合成网片在机器人腹疝修补术中的比较。","authors":"Omar Yusef Kudsi, Georges Kaoukabani, Naseem Bou-Ayash, Fahri Gokcal","doi":"10.4293/JSLS.2022.00071","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>To estimate the average treatment effect on the treated (ATT) and to assess the clinical outcomes in two different types of mesh in robotic Rives-Stoppa (rRS) ventral hernia repair (VHR).</p><p><strong>Methods: </strong>A retrospective analysis of a robotic VHR database between February 1, 2013 and May 31, 2022. Patients who underwent a rRS VHR were included in this study and separated into two groups depending on the mesh used: Synecor<sup>TM</sup> Preperitoneal Biomaterial (Synecor<sup>TM</sup> Pre) and Bard™ Soft. Through propensity score and inverse-probability-treatment-weighting, the ATT was estimated for two scenarios; the first with the treated target having used the Synecor<sup>TM</sup> Pre, the second having used the Bard™ Soft mesh. Adjusted linear regression models, including lingering imbalanced variables, were used for both the primary outcome of the Comprehensive Complication Index (CCI®), and the secondary outcome of the hospital cost.</p><p><strong>Results: </strong>A total of 186 patients who underwent rRS were separated into the two groups (Synecor<sup>TM</sup> Pre mesh, n = 85; Bard™ Soft mesh, n = 101). Adjusted linear regression models for the CCI showed no statistical difference between both groups (p > 0.05), whereas ATT on hospital cost was significantly higher (<i>p</i> < 0.001) in the Synecor<sup>TM</sup> Pre group in both scenarios [(95% confidence interval) = 3882 (2352, 5413) and -5185 (-8213, -2157), respectively].</p><p><strong>Conclusion: </strong>Both mesh materials provided excellent outcomes with no difference in complications or recurrence rates. However, hospital cost was found to be higher in the hybrid mesh group. Long-term follow-up is needed to fully assess the performance of both mesh types in rRS.</p>","PeriodicalId":17679,"journal":{"name":"JSLS : Journal of the Society of Laparoendoscopic Surgeons","volume":"26 4","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/4d/cc/e2022.00071.PMC9840217.pdf","citationCount":"0","resultStr":"{\"title\":\"Comparison of Hybrid Versus Synthetic Mesh in Robotic Rives-Stoppa Ventral Hernia Repair.\",\"authors\":\"Omar Yusef Kudsi, Georges Kaoukabani, Naseem Bou-Ayash, Fahri Gokcal\",\"doi\":\"10.4293/JSLS.2022.00071\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and objectives: </strong>To estimate the average treatment effect on the treated (ATT) and to assess the clinical outcomes in two different types of mesh in robotic Rives-Stoppa (rRS) ventral hernia repair (VHR).</p><p><strong>Methods: </strong>A retrospective analysis of a robotic VHR database between February 1, 2013 and May 31, 2022. Patients who underwent a rRS VHR were included in this study and separated into two groups depending on the mesh used: Synecor<sup>TM</sup> Preperitoneal Biomaterial (Synecor<sup>TM</sup> Pre) and Bard™ Soft. Through propensity score and inverse-probability-treatment-weighting, the ATT was estimated for two scenarios; the first with the treated target having used the Synecor<sup>TM</sup> Pre, the second having used the Bard™ Soft mesh. Adjusted linear regression models, including lingering imbalanced variables, were used for both the primary outcome of the Comprehensive Complication Index (CCI®), and the secondary outcome of the hospital cost.</p><p><strong>Results: </strong>A total of 186 patients who underwent rRS were separated into the two groups (Synecor<sup>TM</sup> Pre mesh, n = 85; Bard™ Soft mesh, n = 101). Adjusted linear regression models for the CCI showed no statistical difference between both groups (p > 0.05), whereas ATT on hospital cost was significantly higher (<i>p</i> < 0.001) in the Synecor<sup>TM</sup> Pre group in both scenarios [(95% confidence interval) = 3882 (2352, 5413) and -5185 (-8213, -2157), respectively].</p><p><strong>Conclusion: </strong>Both mesh materials provided excellent outcomes with no difference in complications or recurrence rates. However, hospital cost was found to be higher in the hybrid mesh group. Long-term follow-up is needed to fully assess the performance of both mesh types in rRS.</p>\",\"PeriodicalId\":17679,\"journal\":{\"name\":\"JSLS : Journal of the Society of Laparoendoscopic Surgeons\",\"volume\":\"26 4\",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2022-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/4d/cc/e2022.00071.PMC9840217.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JSLS : Journal of the Society of Laparoendoscopic Surgeons\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4293/JSLS.2022.00071\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JSLS : Journal of the Society of Laparoendoscopic Surgeons","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4293/JSLS.2022.00071","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
摘要
背景与目的:评估两种不同类型补片在机器人Rives-Stoppa (rRS)腹疝修补术(VHR)中的平均治疗效果和临床效果。方法:对2013年2月1日至2022年5月31日机器人VHR数据库进行回顾性分析。接受rRS VHR的患者被纳入本研究,并根据使用的补片分为两组:SynecorTM Pre -腹膜生物材料(SynecorTM Pre)和Bard™Soft。通过倾向得分和逆概率处理加权,估计了两种情况下的ATT;第一次使用的是SynecorTM Pre,第二次使用的是Bard™Soft mesh。综合并发症指数(CCI®)的主要结局和医院费用的次要结局均采用调整后的线性回归模型,包括持续的不平衡变量。结果:186例rRS患者分为两组(SynecorTM Pre mesh, n = 85;巴德™软网,n = 101)。调整后的线性回归模型显示两组CCI无统计学差异(p > 0.05),而两种情况下SynecorTM Pre组的住院费用ATT均显著高于两组(p < 0.001)[(95%置信区间)分别= 3882(2352,5413)和-5185(-8213,-2157)]。结论:两种补片材料效果良好,无并发症和复发率差异。然而,混合补片组的住院费用较高。需要长期随访,以充分评估两种补片在rRS中的性能。
Comparison of Hybrid Versus Synthetic Mesh in Robotic Rives-Stoppa Ventral Hernia Repair.
Background and objectives: To estimate the average treatment effect on the treated (ATT) and to assess the clinical outcomes in two different types of mesh in robotic Rives-Stoppa (rRS) ventral hernia repair (VHR).
Methods: A retrospective analysis of a robotic VHR database between February 1, 2013 and May 31, 2022. Patients who underwent a rRS VHR were included in this study and separated into two groups depending on the mesh used: SynecorTM Preperitoneal Biomaterial (SynecorTM Pre) and Bard™ Soft. Through propensity score and inverse-probability-treatment-weighting, the ATT was estimated for two scenarios; the first with the treated target having used the SynecorTM Pre, the second having used the Bard™ Soft mesh. Adjusted linear regression models, including lingering imbalanced variables, were used for both the primary outcome of the Comprehensive Complication Index (CCI®), and the secondary outcome of the hospital cost.
Results: A total of 186 patients who underwent rRS were separated into the two groups (SynecorTM Pre mesh, n = 85; Bard™ Soft mesh, n = 101). Adjusted linear regression models for the CCI showed no statistical difference between both groups (p > 0.05), whereas ATT on hospital cost was significantly higher (p < 0.001) in the SynecorTM Pre group in both scenarios [(95% confidence interval) = 3882 (2352, 5413) and -5185 (-8213, -2157), respectively].
Conclusion: Both mesh materials provided excellent outcomes with no difference in complications or recurrence rates. However, hospital cost was found to be higher in the hybrid mesh group. Long-term follow-up is needed to fully assess the performance of both mesh types in rRS.
期刊介绍:
JSLS, Journal of the Society of Laparoscopic & Robotic Surgeons publishes original scientific articles on basic science and technical topics in all the fields involved with laparoscopic, robotic, and minimally invasive surgery. CRSLS, MIS Case Reports from SLS is dedicated to the publication of Case Reports in the field of minimally invasive surgery. The journals seek to advance our understandings and practice of minimally invasive, image-guided surgery by providing a forum for all relevant disciplines and by promoting the exchange of information and ideas across specialties.