{"title":"山区稳定条件下时变滤波时间的性能。","authors":"Manuela Lehner, Mathias W Rotach","doi":"10.1007/s10546-023-00824-y","DOIUrl":null,"url":null,"abstract":"<p><p>Eddy-covariance data from five stations in the Inn Valley, Austria, are analyzed for stable conditions to determine the gap scale that separates turbulent from large-scale, non-turbulent motions. The gap scale is identified from (co)spectra calculated from different variables using both Fourier analysis and multi-resolution flux decomposition. A correlation is found between the gap scale and the mean wind speed and stability parameter <i>z</i>/<i>L</i> that is used to determine a time-varying filter time, whose performance in separating turbulent and non-turbulent motions is compared to the performance of constant filter times between 0.5 and 30 min. The impact of applying different filter times on the turbulence statistics depends on the parameter and location, with a comparatively smaller impact on the variance of the vertical wind component than on the horizontal components and the turbulent fluxes. Results indicate that a time-varying filter time based on a multi-variable fit taking both mean wind speed and stability into account and a constant filter time of 2-3 min perform best in that they remove most of the non-turbulent motions while at the same time capturing most of the turbulence. For the studied sites and conditions, a time-varying filter time does not outperform a well chosen constant filter time because of relatively small variations in the filter time predicted by the correlation with mean flow parameters.</p>","PeriodicalId":9153,"journal":{"name":"Boundary-Layer Meteorology","volume":"188 3","pages":"523-551"},"PeriodicalIF":2.3000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10492749/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Performance of a Time-Varying Filter Time Under Stable Conditions over Mountainous Terrain.\",\"authors\":\"Manuela Lehner, Mathias W Rotach\",\"doi\":\"10.1007/s10546-023-00824-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Eddy-covariance data from five stations in the Inn Valley, Austria, are analyzed for stable conditions to determine the gap scale that separates turbulent from large-scale, non-turbulent motions. The gap scale is identified from (co)spectra calculated from different variables using both Fourier analysis and multi-resolution flux decomposition. A correlation is found between the gap scale and the mean wind speed and stability parameter <i>z</i>/<i>L</i> that is used to determine a time-varying filter time, whose performance in separating turbulent and non-turbulent motions is compared to the performance of constant filter times between 0.5 and 30 min. The impact of applying different filter times on the turbulence statistics depends on the parameter and location, with a comparatively smaller impact on the variance of the vertical wind component than on the horizontal components and the turbulent fluxes. Results indicate that a time-varying filter time based on a multi-variable fit taking both mean wind speed and stability into account and a constant filter time of 2-3 min perform best in that they remove most of the non-turbulent motions while at the same time capturing most of the turbulence. For the studied sites and conditions, a time-varying filter time does not outperform a well chosen constant filter time because of relatively small variations in the filter time predicted by the correlation with mean flow parameters.</p>\",\"PeriodicalId\":9153,\"journal\":{\"name\":\"Boundary-Layer Meteorology\",\"volume\":\"188 3\",\"pages\":\"523-551\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10492749/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Boundary-Layer Meteorology\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.1007/s10546-023-00824-y\",\"RegionNum\":3,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"METEOROLOGY & ATMOSPHERIC SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Boundary-Layer Meteorology","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.1007/s10546-023-00824-y","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"METEOROLOGY & ATMOSPHERIC SCIENCES","Score":null,"Total":0}
The Performance of a Time-Varying Filter Time Under Stable Conditions over Mountainous Terrain.
Eddy-covariance data from five stations in the Inn Valley, Austria, are analyzed for stable conditions to determine the gap scale that separates turbulent from large-scale, non-turbulent motions. The gap scale is identified from (co)spectra calculated from different variables using both Fourier analysis and multi-resolution flux decomposition. A correlation is found between the gap scale and the mean wind speed and stability parameter z/L that is used to determine a time-varying filter time, whose performance in separating turbulent and non-turbulent motions is compared to the performance of constant filter times between 0.5 and 30 min. The impact of applying different filter times on the turbulence statistics depends on the parameter and location, with a comparatively smaller impact on the variance of the vertical wind component than on the horizontal components and the turbulent fluxes. Results indicate that a time-varying filter time based on a multi-variable fit taking both mean wind speed and stability into account and a constant filter time of 2-3 min perform best in that they remove most of the non-turbulent motions while at the same time capturing most of the turbulence. For the studied sites and conditions, a time-varying filter time does not outperform a well chosen constant filter time because of relatively small variations in the filter time predicted by the correlation with mean flow parameters.
期刊介绍:
Boundary-Layer Meteorology offers several publishing options: Research Letters, Research Articles, and Notes and Comments. The Research Letters section is designed to allow quick dissemination of new scientific findings, with an initial review period of no longer than one month. The Research Articles section offers traditional scientific papers that present results and interpretations based on substantial research studies or critical reviews of ongoing research. The Notes and Comments section comprises occasional notes and comments on specific topics with no requirement for rapid publication. Research Letters are limited in size to five journal pages, including no more than three figures, and cannot contain supplementary online material; Research Articles are generally fifteen to twenty pages in length with no more than fifteen figures; Notes and Comments are limited to ten journal pages and five figures. Authors submitting Research Letters should include within their cover letter an explanation of the need for rapid publication. More information regarding all publication formats can be found in the recent Editorial ‘Introducing Research Letters to Boundary-Layer Meteorology’.