{"title":"置换髋关节置换术治疗同侧股骨颈骨折及股骨骨干骨折内固定失败1例。","authors":"Marlon M Mencia, Pablo Pedro Hernandez Cruz","doi":"10.1186/s13037-023-00352-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Ipsilateral femoral neck and hip fractures are uncommon high energy injuries. In the literature no single method of treatment has emerged as superior to the others. A recent publication has documented the successful application of the rendezvous technique using dual-implants for treating these injuries. However in some cases, this technique may fail and revision surgery is required.</p><p><strong>Case presentation: </strong>A 67-year old man sustained ipsilateral fractures of his femur and femoral neck in a road traffic accident. His injuries were treated by a dual construct consisting of a retrograde femoral nail and dynamic hip screw. Three months after surgery the hip screw cut out of the femoral head necessitating revision to a total hip arthroplasty. Surgery was carried out using a single stage two part procedure on a standard operating table without having to reposition or redrape the patient. There were no postoperative complications and at 1 year from surgery the patient is satisfied with the result and has returned to work.</p><p><strong>Conclusion: </strong>Conversion hip arthroplasty in the presence of dual implants is a technically challenging and unpredictable procedure, with an increased risk of complications. Our surgical approach provides a framework for orthopedic surgeons to safely perform this complex procedure.</p>","PeriodicalId":46782,"journal":{"name":"Patient Safety in Surgery","volume":"17 1","pages":"1"},"PeriodicalIF":2.6000,"publicationDate":"2023-01-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9850509/pdf/","citationCount":"0","resultStr":"{\"title\":\"Conversion hip arthroplasty for failed internal fixation of ipsilateral femoral neck and shaft fractures: a case report.\",\"authors\":\"Marlon M Mencia, Pablo Pedro Hernandez Cruz\",\"doi\":\"10.1186/s13037-023-00352-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Ipsilateral femoral neck and hip fractures are uncommon high energy injuries. In the literature no single method of treatment has emerged as superior to the others. A recent publication has documented the successful application of the rendezvous technique using dual-implants for treating these injuries. However in some cases, this technique may fail and revision surgery is required.</p><p><strong>Case presentation: </strong>A 67-year old man sustained ipsilateral fractures of his femur and femoral neck in a road traffic accident. His injuries were treated by a dual construct consisting of a retrograde femoral nail and dynamic hip screw. Three months after surgery the hip screw cut out of the femoral head necessitating revision to a total hip arthroplasty. Surgery was carried out using a single stage two part procedure on a standard operating table without having to reposition or redrape the patient. There were no postoperative complications and at 1 year from surgery the patient is satisfied with the result and has returned to work.</p><p><strong>Conclusion: </strong>Conversion hip arthroplasty in the presence of dual implants is a technically challenging and unpredictable procedure, with an increased risk of complications. Our surgical approach provides a framework for orthopedic surgeons to safely perform this complex procedure.</p>\",\"PeriodicalId\":46782,\"journal\":{\"name\":\"Patient Safety in Surgery\",\"volume\":\"17 1\",\"pages\":\"1\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2023-01-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9850509/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Patient Safety in Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s13037-023-00352-1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Patient Safety in Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13037-023-00352-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SURGERY","Score":null,"Total":0}
Conversion hip arthroplasty for failed internal fixation of ipsilateral femoral neck and shaft fractures: a case report.
Background: Ipsilateral femoral neck and hip fractures are uncommon high energy injuries. In the literature no single method of treatment has emerged as superior to the others. A recent publication has documented the successful application of the rendezvous technique using dual-implants for treating these injuries. However in some cases, this technique may fail and revision surgery is required.
Case presentation: A 67-year old man sustained ipsilateral fractures of his femur and femoral neck in a road traffic accident. His injuries were treated by a dual construct consisting of a retrograde femoral nail and dynamic hip screw. Three months after surgery the hip screw cut out of the femoral head necessitating revision to a total hip arthroplasty. Surgery was carried out using a single stage two part procedure on a standard operating table without having to reposition or redrape the patient. There were no postoperative complications and at 1 year from surgery the patient is satisfied with the result and has returned to work.
Conclusion: Conversion hip arthroplasty in the presence of dual implants is a technically challenging and unpredictable procedure, with an increased risk of complications. Our surgical approach provides a framework for orthopedic surgeons to safely perform this complex procedure.